82
Item
Description
GAP (um)
The distance between left fiber and right fiber
Clad offset before (um) Relative clad offset value between left fiber
and right fiber
Clad offset after (um)
Relative clad offset value between left and
right fiber
6.11.5
Stepping Action
Select splice operation mode.
Full Auto
No pause. However, if there are any errors, pauses will
occur and error message will be displayed.
Step1
Pauses before splicing. (Press
to resume the process)
Step2
Pauses at every step in the process. (Press
to resume
the process)
6.11.6
Common arc power
Any value from 0 to 1023. This value affects all fusion programs.
6.11.7
Clamp up down
Splicer move clamp up down
6.11.8
Clamp buffer
Splicer move down clamp just after close the canopy to prevent shock.
6.11.9
Auto Compensation
Arc Power Compensation
The arc discharge power is corrected by the image of arc discharge.
Position Compensation