52
Parameter Table for Splice
Parameter
Min Max
Description
Offset [µm]
0
99.9 Maximum permissible fiber offset [µm]
Cleave Angle
[deg]
0
90.0 Maximum permissible angle of cleaved
fiber end for splicing to continue [deg]
Loss Limit [dB]
0
15.0 Maximum loss allowed for machine not
to give a splicing error [dB]
Gap Difference
[µm]
0 99.99 Maximum permissible gap difference
before splicing [µm]
Time chart of fusion parameters
Arc power Compensation Table
Arc Power
Cleaning
Arc Power
Fusion Arc
Power
Repeat Arc
Power
Cleaning Power Offset
*1
+
0
0
Repeat Arc Power offset
*1
0
0
+
Environment Compensation
+
+
+
Real Time Arc Control
*2
0
+
+
The items marked with “+” are added at the time of calculating each arc power.
*1 This is a parameter of the splicing program, and can be changed.
*2 Possible to change to “Active” or “Cancel” in “Setting”. Added when set to “Active”.
Arc Power
1st Arc End
Power
0
0
Z Distance Feeding
Gap
Z Push Distance
Z Pull Distance
Collision of Fibers
Pre-fuse Time
Z Pull Start Time
1st Arc Duration
2nd Arc Duration
Time flow
1st Arc
2nd Arc
2nd Arc Start
Power
1st Arc Start
Power
2nd Arc End
Power