TX1330 M1
Upgrade and Maintenance Manual
127
Hard disk drives / solid state drives
In order to permanently remove an operational HDD module that is part of a
RAID array from the server, you first need to delete the array using
ServerView RAID Manager.
V
CAUTION!
All data on all HDDs / SSDs in the array will be lost! Be sure to back
up your data before deleting a RAID array.
For further information, please refer to the "ServerView Suite RAID
Management" user guide.
Ê
If applicable,
"Removing the HDD bay cover" on page 55
7.2.4.2
Removing a 2.5-inch HDD / SSD module
Figure 47: Removing a 2.5-inch HDD / SSD module
Ê
Pinch the green locking clips and fully open the locking lever (see figure
45
).
I
Thereby, the HDD / SSD module is pushed out of its drive bay by
about 1 cm and disconnected from the SAS / SATA backplane.
Ê
Wait about 30 seconds to allow the hard disk drive to spin down.
I
This is not necessary when removing a solid state drive.
Ê
Pull the HDD / SSD module completely out of its bay.