TX1330 M1
Upgrade and Maintenance Manual
83
Basic software procedures
Ê
Select the
Server Mgmt
menu.
Ê
Under
Boot Retry Counter
the current number of remaining boot attempts is
displayed. The value is further decremented with every failed boot attempt
or system reboot resulting from critical system errors.
Ê
Exit the BIOS.
5.2.6.2
Resetting the boot retry counter
The boot retry counter should be reset to its original value concluding every
service task.
I
Please note, if the customer does not know about the original boot
retry values:
If the system boots up and no further errors occur within 6 hours after that
successful boot attempt, the boot retry counter will automatically be reset
to its default value. Please take into account, that the specified number
of boot attempts can only be determined after this period of time.
If the customer knows about the original boot retry values, proceed as follows
to reset or configure the boot retry counter:
Resetting the boot retry counter in the BIOS
Ê
Enter the BIOS.
Ê
Select the
Server Mgmt
menu.
Ê
Under
Boot Retry Counter
press the
[+]
or
[-]
keys to specify the maximum
number of boot attempts (0 to 7).
Ê
Exit the BIOS.
Resetting the boot retry counter using the ServerView Operations
Manager
Ê
In the ServerView Operations Manager
Administration
view, select
Server
Configuration
.
Ê
If more than one server is managed in SVOM, select the target server and
click
Next
.
Ê
From the
Server Configuration
menu pane, choose
Restart Options
.
Ê
Under
Reboot Retries
, specify the maximum number of boot attempts (0 to 7)
in the
Default for reboot tries
field.
Содержание Server PRIMERGY TX1330 M1
Страница 18: ...Upgrade and Maintenance Manual TX1330 M1 Content ...
Страница 30: ...30 Upgrade and Maintenance Manual TX1330 M1 Before you start ...
Страница 98: ...98 Upgrade and Maintenance Manual TX1330 M1 Basic software procedures ...
Страница 120: ...120 Upgrade and Maintenance Manual TX1330 M1 Power supply ...
Страница 158: ...158 Upgrade and Maintenance Manual TX1330 M1 System fan and air duct ...
Страница 216: ...216 Upgrade and Maintenance Manual TX1330 M1 Main memory ...
Страница 336: ...336 Upgrade and Maintenance Manual TX1330 M1 Appendix ...