format
Searching
for
disks...done
AVAILABLE
DISK
SELECTIONS:
0.
c2t50000393B81B3A36d0
<TOSHIBA-MBF2600RC-3706
cyl
46873
alt
2
hd
20
sec
625>
<--
(1)
/pci@8000/pci@4/pci@0/pci@0/scsi@0/iport@f/disk@w50000393b81b3a36,0
/dev/chassis/SYS/HDD00/disk
<--
(2)
1.
c2t500000E01FB332A2d0
<FUJITSU-MBD2600RC-3701
cyl
46873
alt
2
hd
20
sec
625>
<--
(1)
/pci@8000/pci@4/pci@0/pci@0/scsi@0/iport@f/disk@w500000e01fb332a2,0
/dev/chassis/SYS/HDD01/disk
<--
(3)
2.
c2t50000393B81B4D7Ad0
<TOSHIBA-MBF2600RC-3706
cyl
46873
alt
2
hd
20
sec
625>
<--
(1)
/pci@8000/pci@4/pci@0/pci@0/scsi@0/iport@f/disk@w50000393b81b4d7a,0
/dev/chassis/SYS/HDD02/disk
<--
(4)
Specify
disk
(enter
its
number):
5.4.1
How
to
identify
a
disk
slot
To
maintain
an
internal
disk
drive,
you
need
to
know
the
physical
device
name
or
logical
device
name
of
a
drive
to
be
installed
or
removed.
If
a
disk
error
occurs
in
the
system,
from
the
system
console,
you
can
normally
check
for
messages
regarding
a
disk
that
is
likely
to
fail
or
that
has
already
failed.
This
information
is
also
recorded
in
the
/var/adm/messages
file.
In
these
error
messages,
a
failed
internal
disk
drive
is
normally
indicated
with
a
physical
device
name
or
logical
device
name.
In
addition,
depending
on
the
application,
the
slot
number
of
the
disk
may
be
reported.
The
procedure
to
confirm
the
mounting
location
information
on
the
disk
varies
depending
on
the
operating
system.
-
For
Oracle
Solaris
11
For
details,
see
or
"
-
For
Oracle
Solaris
10
For
details,
see
Using
the
format
command
(Oracle
Solaris
11)
1.
Execute
the
format
command
to
confirm
the
disk
slot.
(1)
to
(4)
in
the
following
example
represent:
(1):
Logical
path
name
of
the
disk
(2):
The
disk
is
mounted
in
the
HDD00
slot
(3):
The
disk
is
mounted
in
the
HDD01
slot
(4):
The
disk
is
mounted
in
the
HDD02
slot
Chapter
5
Preparations
Required
for
Maintenance
49
Содержание Oracle M10-1
Страница 1: ...Fujitsu M10 1 SPARC M10 1 Service Manual Manual Code C120 E681 19EN June 2021 ...
Страница 22: ...Fujitsu M10 1 SPARC M10 1 Service Manual June 2021 8 ...
Страница 38: ...Fujitsu M10 1 SPARC M10 1 Service Manual June 2021 24 ...
Страница 42: ...Fujitsu M10 1 SPARC M10 1 Service Manual June 2021 28 ...
Страница 80: ...A Figure 5 11 Releasing the cable guide lock Fujitsu M10 1 SPARC M10 1 Service Manual June 2021 66 ...
Страница 134: ...Fujitsu M10 1 SPARC M10 1 Service Manual June 2021 120 ...
Страница 142: ...Fujitsu M10 1 SPARC M10 1 Service Manual June 2021 128 ...
Страница 148: ...Fujitsu M10 1 SPARC M10 1 Service Manual June 2021 134 ...
Страница 158: ...Fujitsu M10 1 SPARC M10 1 Service Manual June 2021 144 ...
Страница 164: ...Fujitsu M10 1 SPARC M10 1 Service Manual June 2021 150 ...
Страница 176: ...Fujitsu M10 1 SPARC M10 1 Service Manual June 2021 162 ...
Страница 188: ...Fujitsu M10 1 SPARC M10 1 Service Manual June 2021 174 ...
Страница 200: ...Fujitsu M10 1 SPARC M10 1 Service Manual June 2021 186 ...
Страница 214: ...Figure 16 9 Unlocking the cover 3 Remove the microSD card Fujitsu M10 1 SPARC M10 1 Service Manual June 2021 200 ...
Страница 226: ...Fujitsu M10 1 SPARC M10 1 Service Manual June 2021 212 ...
Страница 234: ...Fujitsu M10 1 SPARC M10 1 Service Manual June 2021 220 ...
Страница 248: ...Fujitsu M10 1 SPARC M10 1 Service Manual June 2021 234 ...
Страница 252: ...Fujitsu M10 1 SPARC M10 1 Service Manual June 2021 238 ...