Table
C-5
ping
command
options
Operand/option
Description
Application
hostname
When
you
send
a
probe
packet
to
hostname
,
a
message
is
returned.
Allows
you
to
confirm
that
a
host
is
active
on
the
network.
-g
hostname
Forces
the
probe
packet
to
go
through
the
specified
gateway.
Allows
you
to
test
the
quality
of
individual
routes
by
sending
packets
to
the
target
host
via
the
various
specified
routes.
-i
interface
Specifies
the
interface
to
be
used
for
sending
and
receiving
a
probe
packet.
Allows
you
to
easily
check
the
secondary
network
interface.
-n
Converts
a
host
name
into
an
IP
address
and
then
displays
it.
Allows
you
to
check
the
IP
address
instead
of
the
host
name.
-s
ping
is
repeated
at
an
interval
of
1
second.
Pressing
the
[Ctrl]
+
[C]
keys
stops
ping,
and
then
displays
the
statistics.
Allows
you
to
check
intermittent
or
long-term
network
events.
You
can
view
nighttime
network
events
at
a
glance
by
piping
the
ping
output
to
a
file.
-svR
Displays
the
routes
that
probe
packets
have
passed
through
at
an
interval
of
1
second.
Displays
the
routes
and
hop
counts
of
probe
packets,
allowing
you
to
compare
multiple
routes
to
identify
any
bottleneck.
#
ping
-s
10.24.187.50
PING
10.24.187.50:
56
data
bytes
64
bytes
from
10.24.187.50:
icmp_seq=0.
time=0.555
ms
64
bytes
from
10.24.187.50:
icmp_seq=1.
time=0.400
ms
64
bytes
from
10.24.187.50:
icmp_seq=2.
time=0.447
ms
^C
----10.24.187.50
PING
Statistics----
3
packets
transmitted,
3
packets
received,
0%
packet
loss
round-trip
(ms)
min/avg/max/stddev
=
0.400/0.467/0.555/0.079
#
In
certain
configurations
of
the
ping
command,
the
command
output
allows
you
to
identify
a
network
link
or
a
node
that
has
experienced
a
problem.
The
destination
host
is
specified
by
the
variable:
hostname
.
lists
the
operands/options
of
the
ping
command
and
how
they
are
useful
for
troubleshooting.
The
following
example
shows
the
output
from
the
ping
command.
Fujitsu
M10-1/SPARC
M10-1
Service
Manual
・
June
2021
230
Содержание Oracle M10-1
Страница 1: ...Fujitsu M10 1 SPARC M10 1 Service Manual Manual Code C120 E681 19EN June 2021 ...
Страница 22: ...Fujitsu M10 1 SPARC M10 1 Service Manual June 2021 8 ...
Страница 38: ...Fujitsu M10 1 SPARC M10 1 Service Manual June 2021 24 ...
Страница 42: ...Fujitsu M10 1 SPARC M10 1 Service Manual June 2021 28 ...
Страница 80: ...A Figure 5 11 Releasing the cable guide lock Fujitsu M10 1 SPARC M10 1 Service Manual June 2021 66 ...
Страница 134: ...Fujitsu M10 1 SPARC M10 1 Service Manual June 2021 120 ...
Страница 142: ...Fujitsu M10 1 SPARC M10 1 Service Manual June 2021 128 ...
Страница 148: ...Fujitsu M10 1 SPARC M10 1 Service Manual June 2021 134 ...
Страница 158: ...Fujitsu M10 1 SPARC M10 1 Service Manual June 2021 144 ...
Страница 164: ...Fujitsu M10 1 SPARC M10 1 Service Manual June 2021 150 ...
Страница 176: ...Fujitsu M10 1 SPARC M10 1 Service Manual June 2021 162 ...
Страница 188: ...Fujitsu M10 1 SPARC M10 1 Service Manual June 2021 174 ...
Страница 200: ...Fujitsu M10 1 SPARC M10 1 Service Manual June 2021 186 ...
Страница 214: ...Figure 16 9 Unlocking the cover 3 Remove the microSD card Fujitsu M10 1 SPARC M10 1 Service Manual June 2021 200 ...
Страница 226: ...Fujitsu M10 1 SPARC M10 1 Service Manual June 2021 212 ...
Страница 234: ...Fujitsu M10 1 SPARC M10 1 Service Manual June 2021 220 ...
Страница 248: ...Fujitsu M10 1 SPARC M10 1 Service Manual June 2021 234 ...
Страница 252: ...Fujitsu M10 1 SPARC M10 1 Service Manual June 2021 238 ...