Chapter 3 Component Status
3.24 Port Detail
ETERNUS Web GUI User’s Guide (Operation)
Copyright 2016 FUJITSU LIMITED
P2X0-1260-19ENZ0
176
-
WWN
The WWN of the port is displayed.
"WWN" is displayed when the port mode is "CA", "Remote Adapter (RA)", or "CA/RA".
If the port mode is "Initiator", the display status varies according to the screen. A "-" (hyphen) is
displayed for the CM#x CA#y port information in the [Channel Adapter Detail] screen. This item is not
displayed in the [Port Detail] screen.
-
WWN (Port Name)
The WWPN of the port is displayed.
"WWN (Port Name)" is displayed when the port mode is "Initiator".
If the port mode is not "Initiator", the display status varies according to the screen. A "-" (hyphen) is
displayed for the CM#x CA#y port information in the [Channel Adapter Detail] screen. This item is not
displayed in the [Port Detail] screen.
-
WWN (Node Name)
The WWNN of the port is displayed.
"WWN (Node Name)" is displayed when the port mode is "Initiator".
If the port mode is not "Initiator", the display status varies according to the screen. A "-" (hyphen) is
displayed for the CM#x CA#y port information in the [Channel Adapter Detail] screen. This item is not
displayed in the [Port Detail] screen.
-
Affinity Mode
The affinity mode of the port is displayed.
•
ON
•
OFF
-
TFO Transfer Mode
Whether the TFO transfer mode is enabled or disabled for the target port is displayed.
A "-" (hyphen) is displayed when the port mode is "CA" or "Initiator".
This item is displayed only when "Enable" is selected for the Storage Cluster function.
-
TFO WWN Mode
When the port is being used by the Storage Cluster function, "Custom" is displayed if WWN has been
changed, and "Default" is displayed if no changes have been made.
A "-" (hyphen) is displayed when the port mode is "RA", "CA/RA", or "Initiator".
This item is displayed only when "Enable" is selected for the Storage Cluster function.
•
Custom
•
Default
-
TFO Port
When the port is being used by the Storage Cluster function, "Used" is displayed, and "Unused" is dis-
played when the port is not used.
This item is displayed only when "Enable" is selected for the Storage Cluster function.
•
Used
•
Unused
-
FC Frame Size
The frame size of the port is displayed.
•
512 byte
•
1024 byte
•
2048 byte
-
Part Number
The part number of the port is displayed.
If the part number cannot be acquired, a "-" (hyphen) is displayed.