Error contents
POWER/
MODE
ERROR
PUMP
DOWN
LOW NOISE
PEAK CUT
L1
L2
L3
L4
L5
L6
E: 84. Current sensor error (Outdoor
unit)
■
2
●
■
8
■
4
○
○
○
●
E: 86. High pressure switch error
(Outdoor unit)
■
2
●
■
8
■
6
○
●
●
○
E: 94. Trip detection (Outdoor unit)
■
2
●
■
9
■
4
○
○
○
●
E: 95. Compressor motor control error
(Outdoor unit)
■
2
●
■
9
■
5
○
○
○
●
E: 97. Outdoor unit fan motor error
(Outdoor unit)
■
2
●
■
9
■
7
○
○
●
●
E: 99. 4-way valve error (Outdoor unit)
■
2
●
■
9
■
9
○
○
○
●
E: A1. Discharge temperature error
(Outdoor unit)
■
2
●
■
10
■
1
○
○
○
●
E: A3. Compressor temperature error
(Outdoor unit)
■
2
●
■
10
■
3
○
○
○
●
E: A5. Low pressure error (Outdoor
unit)
■
2
●
■
10
■
5
○
○
○
●
E: AC. Heat sink temperature error
(Outdoor unit)
■
2
●
■
10
■
12
○
○
●
●
●