Temperature set back timer
• The SET BACK timer only changes the set temperature for 7 days, it cannot be used to start
or stop air conditioner operation.
• The SET BACK timer can be set to operate up to two times per day but only one temperature
setting can be used.
• During COOLING/DRY mode, the air conditioner will operate at a minimum of 18°C even if the
SET BACK temperature is set to 17°C or lower.
Case of SET BACK timer on the Cooling operation. (Setting temperature :22°C, SET BACK
temperature :26°C)
SET BACK setting
Operation
temperature
Operation
temperature
26°C
22°C
26°C
22°C
24°C
*1
ON
OFF
OFF
ON
*1: During the SET BACK function,
the setting temperature is changed.
Chenge the setting temperature:
22°C 24°C
5-2. Wired remote control
- (04-24) -
5. Timer operation control
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS