![Fujitsu ABHG18KRTA Скачать руководство пользователя страница 379](http://html.mh-extra.com/html/fujitsu/abhg18krta/abhg18krta_service-manual_118013379.webp)
4-6. Swing operation
¢
Compact cassette type
• To select up/down airflow swing operation
When the swing signal is received, the horizontal louver starts to swing.
– Swinging range
• Cooling mode/dry mode/fan mode: 1 ↔ 4
• Heating mode: 1 ↔ 4
– When the indoor fan is S-LOW or stop mode, the swing operation is interrupted and it stops at
either upper end or bottom end.
¢
Wall mounted type
• To select up/down airflow swing operation
When the swing signal is received, the horizontal louver starts to swing.
– Swinging range
• Cooling mode/dry mode/fan mode (1 to 3): 1 ↔ 4
• Heating mode/fan mode (4 to 6): 3 ↔ 6
– When the indoor fan is S-LOW or stop mode, the swing operation is interrupted and it stops at
either upper end or bottom end.
• To select left/right airflow swing operation(for KMTB model only)
When the swing signal is received, the vertical louver starts to swing.
– Swinging range
• All mode: 1 ↔ 5
– When the indoor fan is S-LOW or stop mode, the swing operation is interrupted and it stops at
either left end or right end.
• To select up/down and left/right airflow swing operation (for KMTB model only)
When the swing signal is received, the horizontal and the vertical louvers start to swing.
¢
Ceiling type
• To select up/down airflow swing operation
When the swing signal is received, the horizontal louver starts to swing.
– Swinging range
• Cooling mode/dry mode/fan mode: 1 ↔ 7
• Heating mode: 1 ↔ 7
– When the indoor fan is S-LOW or stop mode, the swing operation is interrupted and it stops at
either upper end or bottom end.
¢
Floor type
• To select up/down airflow swing operation
When the swing signal is received, the horizontal louver starts to swing.
– Swinging range
• Cooling mode/dry mode/fan mode: 1 ↔ 5
• Heating mode: 1 ↔ 5
– When the indoor fan is S-LOW or stop mode, the swing operation is interrupted and it stops at
either upper end or bottom end.
4-6. Swing operation
- (04-59) -
4. Louver control
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS
Содержание ABHG18KRTA
Страница 4: ......
Страница 5: ...1 GENERAL INFORMATION 2022 08 08 SR_CH01_MU004EG_06 ...
Страница 59: ...2 TECHNICAL DATA AND PARTS LIST 2022 08 08 SR_CH02_MU004EG_11 ...
Страница 62: ......
Страница 212: ...9 17 Model AOHG36KBTA5 02 150 9 PC board diagrams TECHNICAL DATA AND PARTS LIST TECHNICAL DATA AND PARTS LIST ...
Страница 213: ...3 TROUBLESHOOTING 2022 08 08 SR_CH03_MU004EG_07 ...
Страница 216: ......
Страница 316: ...6 2 Outdoor unit 03 100 6 Thermistor resistance values TROUBLESHOOTING TROUBLESHOOTING ...
Страница 317: ...4 CONTROL AND FUNCTIONS 2022 04 13 SR_CH04_MU004EG_08 ...
Страница 320: ......
Страница 403: ...5 FILED WORKING 2022 08 08 SR_CH05_MU004EG_08 ...