Models: ASHG07KMTB, ASHG09KMTB, ASHG12KMTB,
ASHG14KMTB, ASHG07KMCC, ASHG09KMCC, ASHG12KMCC,
and ASHG14KMCC
Check point 1. Check rotation of fan
Rotate the fan by hand when operation is off.
(Check if fan is caught, dropped off or locked motor)
→ If fan or bearing is abnormal, replace it.
Check point 2. Check resistance of indoor fan motor
Refer to below. Circuit-test “Vm” and “GND” terminal
NOTE:
Vm: DC voltage, GND: Earth terminal
→ If they are short-circuited (below 300 kΩ), replace indoor fan motor and controller PCB.
Pin number
(wire color)
Terminal function
(symbol)
1 (Blue)
Feed back (FG)
2 (Yellow)
Speed command (Vsp)
3 (White)
Control voltage (Vcc)
4 (Black)
Ground terminal (GND)
5
No function
6 (Red)
DC voltage (Vm)