Model: AOHG36KBTA5
Fan speed is defined by outdoor temperature and compressor frequency.
Unit: rpm
Fan step
Cooling or dry
Heating
S-HIGH
—
1,200
13
1,150
—
12
1,150
—
11
1,150
—
10
1,080
1,200
9
920
1,150
8
860
1,080
7
770
990
6
680
860
5
630
800
4
560
700
3
490
640
2
390
600
1
270
570
• When the compressor frequency increases, the outdoor fan speed also changes to the higher
speed.
• When the compressor frequency decreases, the outdoor fan speed also changes to the lower
speed.
NOTE:
After defrost control on the heating mode, the fan speed is kept higher regardless of the
compressor frequency.
Fan speed after defrost control: 1,200 rpm