1-4. Rotation number of compressor at normal start-up
¢
Models: AOHG30KBTA4 and AOHG36KBTA5
Rotation number of the compressor soon after starting is controlled as below.
Rotation number I
Rotation number II
Rotation number III
Rotation number IV
Rotation number V
Rotation number VI
Time 1
Time 2
Time 3
Time 4
Time 5
Time 6
Rotation number
(rps)
I
II
III
IV
V
VI
35
52
64
71
89
97
Time (sec)
1
2
3
4
5
6
60
140
170
200
350
410
1-4. Rotation number of compressor at normal start-up
- (04-16) -
1. Rotation number control of compressor
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS
Содержание ABHG18KRTA