![Fujitsu AB*14LBAJ Скачать руководство пользователя страница 93](http://html.mh-extra.com/html/fujitsu/ab-14lbaj/ab-14lbaj_service-instruction_118000093.webp)
Check Point : AU*12/ 14/ 18LBAB
(AC)
VIOLET
BLUE
YELLOW
PINK
RED
BLACK
WHITE
Thermal protector
140°C
Check each winding resistance of the motor
If Resistance value is abnormal, replace motor.
02-55
Red Pink
Pink Violet
Violet Blue
Blue Black
White Red
Read Wire
431
8%
10.7
8%
55.5
8%
55.5
8%
35.7
8%
Resistance value
at 20°C
AU*18LBAB
Red Pink
Pink Violet
Violet Blue
Blue Black
White Red
Read Wire
427
8%
191
8%
191
8%
92.8
8%
92.8
8%
Resistance value
at 20°C
AU*12/ 14LBAB
Pr
Check Point : AS*18/ 24LBAJ
(AC)
BLUE
YELLOW
RED
BLACK
WHITE
Thermal protector
140°C
Check each winding resistance of the motor
If Resistance value is abnormal, replace motor.
Blue Red
Blue Black
White Red
Read Wire
129
8%
21.0
8%
277
8%
Resistance value
at 20°C
Pr
Check Point : AS*7/ 9/ 12LMACW
Check each winding resistance of the motor
If Resistance value is abnormal, replace motor.
White Yellow
Black Yellow
Read Wire
138
8%
136
8%
Resistance value
at 20°C
(AC)
Thermal protector
WHITE
YELLOW
BLACK
Pr
Содержание AB*14LBAJ
Страница 38: ...2 TROUBLE SHOOTING R410A INVERTER MULTI Universal Floor Ceiling Duct Cassette Wall Mounted Floor type ...
Страница 95: ...3 REPLACEMENT PARTS R410A INVERTER MULTI Universal Floor Ceiling Duct Cassette Wall Mounted Floor type ...
Страница 97: ...Thermistor Heat exchanger temp 2 way valve Liquid 3 way valve Gas 03 02 Thermo Holder Thermistor Outdoor Temp ...
Страница 116: ...1116 Suenaga Takatsu ku Kawasaki 213 8502 Japan May 2008 Printed in Japan ...