![Fujitsu AB*14LBAJ Скачать руководство пользователя страница 24](http://html.mh-extra.com/html/fujitsu/ab-14lbaj/ab-14lbaj_service-instruction_118000024.webp)
01-21
6. COMPRESSOR CONTROL
1. OPERATION FREQUENCY RANGE
The operation frequency of the compressor is different based on the operation mode as
shown in the table 4.
Cooling
Heating
Min
Max
Min
Max
AO*18LMAK2
15Hz
80Hz
15Hz
95Hz
AO*24LMAM2
AO*30LMAW4
15Hz
80Hz
15Hz
95Hz
15Hz
90Hz
20Hz
95Hz
(Table 4 : Compressor Operation Frequency Range)
2. OPERATION FREQUENCY CONTROL AT START UP
2-1. For AO*18L/ 24L
The compressor frequency soon after the start-up is controlled as shown in Figure 10-1.
(Fig.10-1 : Compressor Control at Start-up)
56Hz
56Hz
40Hz
46sec
60sec
80sec
160sec
80Hz
Hold
2-2. For AO*30LMAW4
The compressor frequency soon after the start-up is controlled as shown in Figure 10-2.
(Fig.10-2 : Compressor Control at Start-up)
180sec
60sec
120sec
120sec
720sec
1
2
1 Discharge pipe temp. > 30°C
2 Discharge pipe temp. < 30°C
=
Hold
Содержание AB*14LBAJ
Страница 38: ...2 TROUBLE SHOOTING R410A INVERTER MULTI Universal Floor Ceiling Duct Cassette Wall Mounted Floor type ...
Страница 95: ...3 REPLACEMENT PARTS R410A INVERTER MULTI Universal Floor Ceiling Duct Cassette Wall Mounted Floor type ...
Страница 97: ...Thermistor Heat exchanger temp 2 way valve Liquid 3 way valve Gas 03 02 Thermo Holder Thermistor Outdoor Temp ...
Страница 116: ...1116 Suenaga Takatsu ku Kawasaki 213 8502 Japan May 2008 Printed in Japan ...