![Fujitsu AB*14LBAJ Скачать руководство пользователя страница 28](http://html.mh-extra.com/html/fujitsu/ab-14lbaj/ab-14lbaj_service-instruction_118000028.webp)
01-25
The DAY OFF setting is only available for days for which weekly settings already exist.
The SET BACK timer only changes the set temperature for 7 days, it cannot be used to start or stop
air conditioner operation.
The SET BACK timer can be set to operate up to two times per day but only one temperature setting
can be used.
During the COOL/DRY mode, the air conditioner will operate at a minimum of 18
°
C even if
the SET BACK temperature is set to 17
°
C or lower.
The DAY OFF setting can only be set one time. The DAY OFF setting is cancelled automatically
after the set day has passed.
Normal
Next day setting
If the operating time carries over to the next day (during a next day setting), the effective
DAY OFF range will be set as shown below.
2-2. DAY OFF setting
3. TEMPERATURE SET BACK TIMER
Stop mode
Stop mode
Operation mode
Stop mode
Operation mode
Preceding day
Next day
DAY OFF
Stop mode
Stop mode
Operation mode
Stop mode
Operation mode
DAY OFF
Setting day
Preceding day
Next day
Setting day
Case of SET BACK timer on the Cooling operation.
( Setting temperature :22
°
C, SET BACK temperature :26
°
C)
SET BACK setting
Operation
temperature
Operation
temperature
26
°
C
22
°
C
26
°
C
22
°
C
24
°
C
*1
ON
OFF
OFF
ON
*1: During the SET BACK function,
the setting temperature is changed.
Chenge the setting temperature:
22
°
C 24
°
C
Содержание AB*14LBAJ
Страница 38: ...2 TROUBLE SHOOTING R410A INVERTER MULTI Universal Floor Ceiling Duct Cassette Wall Mounted Floor type ...
Страница 95: ...3 REPLACEMENT PARTS R410A INVERTER MULTI Universal Floor Ceiling Duct Cassette Wall Mounted Floor type ...
Страница 97: ...Thermistor Heat exchanger temp 2 way valve Liquid 3 way valve Gas 03 02 Thermo Holder Thermistor Outdoor Temp ...
Страница 116: ...1116 Suenaga Takatsu ku Kawasaki 213 8502 Japan May 2008 Printed in Japan ...