21. VARIOUS PROTECTIONS
1. DISCHARGE GAS TEMPERATURE OVER RISE PREVENTION CONTROL
The discharge gas thermosensor (discharge thermistor : Outdoor side) will detect discharge gas
temperature.
When the discharge temperature becomes higher than 110
°C
,the compressor frequency
is decreased 10 Hz, and it continues to decrease the frequency for 10 Hz every 120 seconds until
the temperature becomes lower than 110
°C
.
When the discharge temperature becomes lower than 105
°C
,the control of the compressor
frequency is released.
When the discharge temperature becomes higher than 120
°C
,the compressor stops.
When the discharge temperature becomes lower than 80
°C
,the compressor operates.
2. CURRENT RELEASE CONTROL
01-33
The compressor frequency is controlled so that the outdoor unit input current does not exceeds
the current limit velue that was set up with the outdoor temperature.
The compressor frequency returns to the designated frequency of the indoor unit at the time
when the frequency becomes lower than the release value.
3. ANTI-FREEZING CONTROL (Cooling mode)
The compressor frequency decreases on cooling mode when the indoor heat exchanger
temperature sensor detects the temperature lower than 3
°C.
Then, the anti-freezing control is released when it becomes higher than 6
°C.
(Fig 13 : Anti-freezing Protection Operation / Release Temperature)
Indoor heat exchange
temperature
3
°C
6
°C
12
°C
The compressor frequency is
decreased 10Hz every 120 seconds.
Compressor OFF : Hold
Compressor ON : Release of protection
Hold
Release of protection
Содержание AB*14LBAJ
Страница 38: ...2 TROUBLE SHOOTING R410A INVERTER MULTI Universal Floor Ceiling Duct Cassette Wall Mounted Floor type ...
Страница 95: ...3 REPLACEMENT PARTS R410A INVERTER MULTI Universal Floor Ceiling Duct Cassette Wall Mounted Floor type ...
Страница 97: ...Thermistor Heat exchanger temp 2 way valve Liquid 3 way valve Gas 03 02 Thermo Holder Thermistor Outdoor Temp ...
Страница 116: ...1116 Suenaga Takatsu ku Kawasaki 213 8502 Japan May 2008 Printed in Japan ...