01-10
5-6. For AG*F Type
42°C
30°C
31°C
Indoor heat exchanger
temperature
Indoor heat exchanger
temperature
When the compressor operates, the maximum value of the indoor fan speed is set as shown in Figure 9,
based on the detected temperature by the indoor heat exchanger sensor on heating mode.
When the compressor does not operate, the indoor fan motor operates [S-Lo] mode.
( Fig.9 : Cool Air Prevention Control )
< [Hi] setting >
Hi
Me
Lo
Cool air
prevention
39°C
37°C
34°C
29°C
24°C
39°C
29°C
Indoor heat exchanger
temperature
Indoor heat exchanger
temperature
< The other of [Hi] setting >
S-Lo
Lo (Qu)
Cool air
prevention
37°C
30°C
31°C
24°C
Setting
FAN mode
S-Lo
During the dry mode operation, the fan speed setting can not be changed. ( S-Lo )