background image

TX200 S4

Service Supplement

45

Index

2.5" HDD backplane

32

43

3.5" HDD backplane

30

42

C

chassis ID board

36

E

ESD (devices sensitive to electrostatic 

discharge)

15

F

Front USB cable

23

I

intrusion detection switches

34

L

laser information

15

light emitting diode (LED)

15

lithium battery

13

M

meaning of the symbols

8

N

notational conventions

8

O

operating panel board

20

41

P

Power backplane

26

44

S

standard PS

24

system board

37

T

target group

5

Содержание PRIMERGY TX200 S4

Страница 1: ...PRIMERGY TX200 S4 Server Service Supplement Edition December 2007...

Страница 2: ...a consistently high quality standard and user friendliness this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DI...

Страница 3: ...er 18 4 1 2 2 Removing the rack front cover 18 4 1 3 System fans and traverse 19 4 1 3 1 Removing the system fan 1 19 4 1 3 2 Removing the system fan 2 19 4 1 3 3 Removing the traverse with the air du...

Страница 4: ...tents 4 9 Replacing the chassis ID board 36 4 10 Replacing the system board 37 5 Appendix 41 5 1 Board layout 41 5 1 1 Operating panel board 41 5 1 2 3 5 HDD backplane 42 5 1 3 2 5 HDD backplane 43 5...

Страница 5: ...PS and redundant system fans 1 1 Overview of the documentation Concept and target groups This Service Supplement completes the information given in the Operating Manual the Options Guide and the Techn...

Страница 6: ...lation and operation among other things External ports Operation Configuration of the server Installation of the rack mounting kit Troubleshooting Installation removal of all hot plug components hot p...

Страница 7: ...ce Panel Installing expansion boards in the PCI slots Inserting the RAID key Installing a parallel interface Converting to hot plug PS and to redundant fans Converting from the floorstand model to the...

Страница 8: ...tems Quotation marks indicate names of chapters and terms that are being emphasized describes activities that must be performed in the order shown V CAUTION pay particular attention to texts marked wi...

Страница 9: ...the Options Guide for the server and the Technical Manual for the system board Shut down the server correctly switch it off pull out the power plug and open the server as described in the chapter Repl...

Страница 10: ......

Страница 11: ...nd on the outside of the machine Wait until the device has acclimatized to room temperature and is absolutely dry before starting it up Material damage may be caused to the device if this requirement...

Страница 12: ...data cables to peripheral devices are adequately shielded To the LAN wiring the requirements apply in accordance with the standards EN 50173 and EN 50174 1 2 As minimum requirement the use of a protec...

Страница 13: ...e g lightning symbol may only be opened removed or exchanged by authorized qualified personnel The hot plug power supply units are exceptions to this rule The warranty expires if the device is damaged...

Страница 14: ...server s CD DVD drive in order to prevent data loss equipment damage and injury Check each CD DVD for damage cracks breakages etc before inserting it in the drive Note that any additional labels appli...

Страница 15: ...ive components Systems and components that might be damaged by electrostatic discharge ESD are marked with the following label Figure 1 ESD label When you handle components fitted with ESDs you must o...

Страница 16: ...or this purpose to connect yourself to the system unit as you install components Place all components on a static safe base I You will find a detailed description for handling ESD components in the re...

Страница 17: ...t down the server correctly If your operating system has not switched off the server press the on off switch Pull all power connectors out of the power outlets Open the latch The opening of the latch...

Страница 18: ...n the rack cabinet it can make sense to remove it from the cabinet You will find a detailed description in the Options Guide or the Operating Manual Disconnect all cables on the rear side of the serve...

Страница 19: ...S on the system board Pull the lock upward and swivel the system fan 2 forward Take out the system fan 2 downward 4 1 3 3 Removing the traverse with the air duct over the main memory Remove the system...

Страница 20: ...move the front cover or the rack front cover as described in the section Preparation on page 17 Remove the system fan 1 as described in the section Removing the system fan 1 on page 19 Disconnect the...

Страница 21: ...ng panel board Figure 3 Releasing the lower hook Press the lower hook upward see the arrow Figure 4 Pulling out the operating panel board with its holder Pull the operating panel board out with its ho...

Страница 22: ...the operating panel board Insert the new operating panel board in the holder Connect the operating panel cable to the operating panel board Push the holder in the housing Connect the operating panel c...

Страница 23: ...Notice the routing of the cable Figure 6 Installed Front USB cable Remove the two screws see the circles Pull the USB connector together with the Front USB cable frontward out of the housing Thread t...

Страница 24: ...erse as described in section System fans and traverse on page 19 Disconnect all power cables from the system board and the drives see the cabling plans in the Appendix of the Options Guide Thread the...

Страница 25: ...ew power supply unit Remove the mounting bracket from the defective power supply unit and mount it onto the new power supply unit two screws Figure 9 Mounting bracket centering tab Push the new power...

Страница 26: ...all power plugs for a detailed description see the Options Guide 4 5 Replacing the Power backplane Open the server as described in the section Preparation on page 17 Remove the system fan 1 the syste...

Страница 27: ...e server must be disconnected to the main voltage because of energy hazard on the Power backplane Remove the screw see the circle and take out the PS safe guard Take care that the screw doesn t fall i...

Страница 28: ...guides Take out the Power backplane Insert the new Power backplane and push the Power backplane in direction of the front side until it engages in the PS cage guides Fasten the Power backplane with on...

Страница 29: ...one screw Reinstall the hot plug power supply unit s Reinstall the traverse the system fan 2 and the system fan 1 for a detailed description see the Options Guide Close the server and connect all pow...

Страница 30: ...der Open the server as described in the section Preparation on page 17 Remove all the hot plug hard disk drives for a description see the Operating Manual V CAUTION Check if all hard disk drives are u...

Страница 31: ...ght angle Then lower the backplane holder Metal tongues on the lower edge of the backplane holder ensure that it is automat ically centered Push the backplane holder against the hard disk cage until t...

Страница 32: ...e server as described in the section Preparation on page 17 Remove all the hot plug hard disk drives for a description see the Operating Manual V CAUTION Check if all hard disk drives are uniquely ide...

Страница 33: ...inst the hard disk cage at a slight angle Hook the backplane in the upper edge and then lower the backplane Metal tongues on the upper edge of the hard disk cage ensure that it is automatically center...

Страница 34: ...de floorstand model or the top rack model of the accessible drives the other switch at the front cover over the hard disk cage The two intrusion detection switches are serially connected on one cable...

Страница 35: ...r on the system board see also the Technical Manual of the system board Plug the new intrusion switch cable to the connector on the system board Route the intrusion switch cable as before Position the...

Страница 36: ...he temperature correctly to enable the server management to display the correct system picture to install the server using ServerStart The chassis ID board is mounted between the hard disk cage and th...

Страница 37: ...r as described in the section Preparation on page 17 Lay the server on a table with the uncovered side facing upward Place the server in such a way that the feet can project over the edge Remove all e...

Страница 38: ...ll the connectors out of the connector panel Check the settings on the new system board for a description see the Technical Manual of the system board Insert the system board by holding it at a slight...

Страница 39: ...ions Guide If removed before Insert the RAID key for a description see the Options Guide Install all controllers in their former slots for a description see the Operating Manual and Options Guide Rein...

Страница 40: ......

Страница 41: ...pendix 5 1 Board layout I The board layout of the system board is described in the Technical Manual of the system board D2509 5 1 1 Operating panel board Part number A3C40085518 1 Connector operating...

Страница 42: ...42 Service Supplement TX200 S4 Board layout Appendix 5 1 2 3 5 HDD backplane Part number A3C40086258 1 Connector power cable 2 Connector SATA cable 1 2...

Страница 43: ...TX200 S4 Service Supplement 43 Appendix Board layout 5 1 3 2 5 HDD backplane Part number A3C40086493 1 Connector SAS cable 2 Connector power cable 1 2...

Страница 44: ...S4 Board layout Appendix 5 1 4 Power backplane Part number A3C40087293 No Xn connector Connector for cable 1 X3 T26139 Y3758 V5 SNP A3C40087908 2 X4 T26139 Y3952 V2 SNP A3C40087920 3 X5 T26139 Y3952...

Страница 45: ...ensitive to electrostatic discharge 15 F Front USB cable 23 I intrusion detection switches 34 L laser information 15 light emitting diode LED 15 lithium battery 13 M meaning of the symbols 8 N notatio...

Страница 46: ......

Страница 47: ...tsu com Copyright Fujitsu Technology Solutions 2009 Hinweise zum vorliegenden Dokument Zum 1 April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu bergegangen Diese neue Tochte...

Отзывы: