34
Service Supplement
TX200
S4
Replacing the intrusion switches
Replacement routines
4.8
Replacing the intrusion switches
In the floorstand model two intrusion detection switches monitor the removing
of the left side cover and the hard disk cover. In the rack model only one
intrusion switch is active, this one monitors the removing of the top cover.
One switch is situated at the side (floorstand model) or the top (rack model) of
the accessible drives, the other switch at the front cover over the hard disk cage.
The two intrusion detection switches are serially connected on one cable and
have to be replaced in pairs.
Ê
Open the server and remove the front cover or the rack front cover as
described in the
section “Preparation” on page 17
.
Figure 16: Removing the intrusion switch 1
Ê
Press the two hooks of the intrusion switch inward (see the arrows) and take
out the intrusion switch.
Ê
Take the intrusion switch cable out of the cable clamp.
V
CAUTION!
Note the cable routing.