26
Service Supplement
TX200
S4
Replacing the Power backplane
Replacement routines
Ê
Thread the power cables which are used through the opening of the PS
separation plate. All the rest of the power cables remain in the standard PS
bay.
Ê
Connect all power cables to the system board and the drives (see the cabling
plans in the Appendix of the Options Guide).
Ê
Fasten the power supply unit to the rear of the server (see
figure 7 on
page 24
).
Ê
Reinstall the traverse, the system fan 2 and the system fan 1 (for a detailed
description see the Options Guide).
Ê
Close the server and connect all power plugs (for a detailed description see
the Options Guide).
4.5
Replacing the Power backplane
Ê
Open the server as described in the
section “Preparation” on page 17
.
Ê
Remove the system fan 1, the system fan 2 and the traverse as described in
section “System fans and traverse” on page 19
.
Ê
Push the green latch of the hot-plug power supply unit upward and pull the
power supply unit simultaneously out of the PS cage using the handle (see
also the Operating Manual).
Ê
If a second hot-plug power supply unit has been installed, remove this one
in the same way (an installed dummy cover can rest in place).
I
The Power backplane in the floorstand model is positioned directly under
the top cover and it makes sense to lay the server on a table with the
uncovered side facing upward.