TX200 S4
Service Supplement
37
Replacement routines
Replacing the system board
Ê
Close the server and connect all power plugs (for a detailed description see
the Options Guide).
I
After installing the new chassis ID board, it is necessary to program the
Chassis ID prom with the help of the "Chassis ID Prom Tool" to enable
ServerView and ServerStart to identify the system. The tool can be
downloaded from the Fujitsu Siemens Computers Service and Support
page (URL:
http://extranet.fujitsu-siemens.com/service/information/intelservers/tools
).
4.10
Replacing the system board
Ê
Open the server as described in the
section “Preparation” on page 17
.
Ê
Lay the server on a table with the uncovered side facing upward. Place the
server in such a way that the feet can project over the edge.
Ê
Remove all external cables.
Ê
Remove the system fan 1, the system fan 2 and the traverse as described in
section “System fans and traverse” on page 19
.
Ê
Remove all controllers from their slots (for a description see the Operating
Manual and the Options Guide). Take note of the slots of the controllers and
the cabling.
Ê
If installed: Remove the RAID key (for a description see the Options Guide).
Ê
Remove the heat sinks and the processors (for a description see the Options
Guide).
Ê
Remove the memory modules (for a description see the Options Guide).
Ê
Remove all cables which may be connected to the system board.