Hot-plug Power Supply Units
Hot-plug/Hot-swap Components
8.1.1
Replacing the Hot-plug Power Supply Unit
Figure 31: Unlocking and removing the power supply unit
V
CAUTION!
Before replacing a non defective hot-plug power supply unit in a non-
redundant configuration (only one power supply unit present) the server
must be switched OFF.
Ê
Remove the cable from the installed power supply unit.
Ê
Push the locking bar of the installed power supply unit towards the power
plug (1).
Ê
Hold the bar firmly and pull the power supply unit out of the location in the
direction marked (2).
Ê
Push the locking bar of the power supply unit that has to be installed towards
the power plug and hold it in this position.
Ê
Insert the power supply unit into the free location.
Ê
Lock the power supply unit with the bar such that it engages firmly in the
groove of the mounting frame.