Installing/Removing the Rack Model
Hardware Installation
Ê
Mount the necessary manufacturer original parts (like support bracket or
cable management).
I
Sometimes a number of parts of the delivered mounting kit cannot be
used because original parts of the 3rd-Party Rack are to be used.
Ê
Mount the supplied four assembly brackets on the telescopic rails as
described in section “Mounting into the PRIMECENTER Rack” on page 32.
Ê
Mount the assembled telescopic rails with the brackets in the 3rd-Party Rack
as described in section “Mounting into the PRIMECENTER Rack” on
page 32.
Ê
Mount the server (see section “Installing the Server” on page 44).
Ê
Route the cables as described in the original manual of the Rack.
4.4.5
Installing the Server
V
CAUTION!
At least two people are needed to position the server in the rack.
Figure 18: Pulling the telescopic bar out
Ê
Pull the mounted telescope bars completely out toward the front. They must
click into place so that you can no longer push them back.