Page 58
§ 6.2.2.
Software Upgrade with RS-232C cable
§ 6.2.2.1
Install of PCUG software
Before using PCUG, install as follows:
1)
Click “SETUP.EXE”
2)
Select folder to install. Default is “C:¥Program Files¥SY012 ROM Upgrade”. Do not change
the folder, except for special reason.
3)
Click “Computer Mark ICON”.
4)
Automatically installed.
5)
After install, making “Short Cut of PCUG” to the desktop of PC is convenience in the case
of upgrading.
<NOTICE> PCUG software can be executed Windows® 95/98.
§ 6.2.2.2
Upgrading of software.
1)
Close all windows applications. Other applications (especially, E-Mail applilications ) has
possibility to prevent communication between splicer and PC. Just in case, turn the screen
saver of PC to OFF.
2)
Connect splicer to PC using RS232C cross cable. Please refer to section 8.3.3.
3)
PCUG program (SY012 Upgrade) start from “Windows Start Menu”. Icon of windows menu
is blue circle.
4)
Select COM port “COM1” or “COM2”.
5)
Select ROM data file.
6)
ROM data file extract automatically. Please wait 1 or 2 minutes. Wait time is decided by the
performance of PC.
7)
Confirm the “Model Name” and “ROM Version” shown in the right side of the window. For
example, Model Name is “FSM-40S”, Version Name is “01.10”.
8)
Confirm that splicer power is off or not. If power is on, turn the power off and click “OK”.
9)
Turn the splicer power on. Then 4 buttons are shown, and select baud rate 38400 for the first
time. Baud rate of splicer is automatically set. If buttons are not shown, confirm the
connection between PC and splicer and try again.
10)
Confirm the previous software version, and click “OK”.
11)
Wait until upgrading.
Wait time is about
5 minutes.
(In the case of 38400 bps.)
10 minutes.
(In the case of 19200 bps.)
13 minutes.
(In the case of 14400 bps.)
20 minutes.
(In the case of 9600 bps.)
12)
If upgrade failure, error message is shown on the window. In this case, try again and select
lower baud rate at the step 7. Some devices installed to PC have the possibility of preventing
the communications between PC and splicer.
13)
After finishing upgrade, confirm the value of check sum shown on the right down corner of
window. The value of check sum is announced by KOKAI-M with the file of “Software
Version History of FSM-40S”.
14)
In the case of upgrading other splicer, click “Y”. On the other hand, in the case of finishing,