Page 48
Set the infrared ray by the spot sensor on the center of the radiator
Fig. 4.18.3
Note1: Sensor type is as follows: Japan Sensor Co. Ltd. Thermo Spot Sensor TMZ51-500-5E3-2
Note2: You must set the radiation ratio value before the heater adjustment as follow.
1.
Push the “MODE” key and “Left” key at once.
2.
Push the “Up” or “Down” key to change the far right variable.
3.
Push the “Left” key to shift the cursor left. Press “Up” or “Down” to change the value of that
variable.
4.
Set the radiation ratio value at 0.930, push the “ENT” key.
5.
Push the “MENU” key 6 more times to complete the operation.
Note3: The tool for fixing the thermo spot sensor can be constant 50mm distance between the sensor
and the radiator plate. This distance is this thermo spot sensor specification.
Note4: Use thermo sensor only on the new type tube heater (e.g.FSM-16R and 30R).
•
Method 2 -
Thermo couple sensor. Fig. 4.18.4 illustrates how to use thermo couple sensor on the
heat emission plate.
Heat Sinker
(Shin-etsu Chemical Co. Ltd. Oil Compound KS-609
Thermocouple
Radiator plate
Center of radiator plate
Fig. 4.18.4
Содержание FSM-40S