FUSION SPLICER 90S Rev5
29
Operation mode
Selection of the operation mode
Each operation mode consists of parameters shown below so that operation of
the equipment can be customized.
You can change the operation of the fusion splicer’s automated features
according to the operator’s speed and preferences.
Parameter
Description
Operation mode
Auto-LR
Before splicing: Start splicing automatically after setting fibers
on left and right sides.
After splicing: Proof test, wind-protector opening, and sheath
clamp opening are automatically performed.
Auto
Before splicing: Start splicing automatically after setting fibers
on left and right sides.
After splicing:
Wind-protector opening and proof test are
simultaneously done. Perform sheath clamp
opening manually.
Norm-LR
Before splicing: Start splicing automatically after setting fibers
on left and right sides.
After splicing:
If press SET key, proof test, wind-protector
opening and sheath clamp opening are
simultaneously done.
Normal
Before splicing: Start splicing automatically after setting fibers
on left and right sides.
After splicing:
If press SET key, proof test and wind-protector
opening are simultaneously done. Perform
sheath clamp opening manually.
manual
Before splicing: If press SET key, start splicing.
After splicing:
If press SET key, proof test and wind-protector
opening are simultaneously done. Perform
sheath clamp opening manually.
A continuation of the operation mode parameter
Parameter
Description
Operation mode
Customized
Operation mode
Sheath clamp auto release
Setup of "ON" or "OFF" can be chosen for triggering sheath
clamp opening.
Auto start trigger
Options of "Fiber Set", "Cover Close", and "OFF" can be
selected for triggering when the fusion splicer begins the
splicing process.
Cover close reaction time
Time between setting the fibers in the fusion splicer until the
wind-protector closes.
Wind-protector motion (At the time of customized was
selected)
Power on
Setup of wind-protector motion at the time of power on
"open" or "close".
Reset
Setup of wind-protector motion at the time of Reset is
pressed "open" or "close".
Finish
Setup of wind-protector motion after splicing: "open" or
"close".
Error
Setup of wind-protector motion at the time of error "open" or
"close".