Stripper Setting Menu
This menu enables parameter selection to control the fusion splicer interface with
the ribbon fiber stripper RS02/03.
Parameter list of Stripper Setting (1 of 2)
Parameter
Descriptions
Heat Settings
Heat Parameter Control
Selects the machine to control the heater parameter
of RS02/03.
[OFF]: RS02/03 works according to the heat
parameters saved in the internal memory of
RS02/03.
[ON]: The fusion splicer controls RS02/03 with the
fusion splicer parameters set in [Splice Mode].
Heat Temperature Level
Sets the heater temperature level of the stripper.
Note: This parameter is not used when selecting the
“OFF” on “Heat Parameter Control”.
Heat Finish Time
Sets the heating time of the stripper.
Note: This parameter is not used when selecting the
“OFF” on “Heat Parameter Control”.
Parameter list of Stripper Setting (2 of 2)
Parameter
Descriptions
ECO Settings
ECO Mode Control By
Selects the machine to control the parameters in ECO
mode of RS02/03. .
[Stripper]: The parameters in ECO mode saved in the
internal memory of RS 02/03 are used.
[Splicer]: The fusion splicer controls the ECO mode of
RS02/03 with parameters that set into the
memory of fusion splicer.
ECO Mode
Toggles ECO mode ON/OFF.
Note: This parameter is disable when selecting the
“Splicer” on “ECO Mode Control by”.
Temperature Keeping
Sets the time delay before ECO mode initiates.
Buzzer Settings
Buzzer Volume
Sets buzzer volume and under what conditions it is
activated.
Power On (Only RS03)
Power Off (Only RS03)
Heat Finish
Auto Shut Down
(Only RS03)
End of Charging
(Only RS03)
Alarm Settings
Blade Replacement
Sets value for number of operations before blade
replacement. The stripper informs the user of the
need for replacement by changing the color of the
“Strip window” in READY screen.
Low Battery
(Only RS03)
Sets value for battery capacity before recharging.
The stripper informs the user of the need for
recharging by changing the color of the “Strip window”
in READY screen.
Others
Auto Shut Down Time
Sets the time for automatic shutoff. This preserves
battery life of the RS03 stripper if it is not being used.
Device Name
Sets the name of the RS02/03 stripper.
These parameters can’t be selected when the wireless data
communication function is unavailable.
It is necessary to set “Heater Parameter Control” “ON” when controlling
the RS02/03 by the fusion splicer.