FUSION SPLICER 90S Rev5
62
Attenuation splice mode
Use this splice mode when you need intentionally splice loss by making axial offset.
Select AT1 or AT2 from Fiber type.
Splice mode
Description
AT1
(SM)(DS)
[AT1] creates an intentional core axial offset and splices
fibers. [AT1] mode provides an estimated splice loss, but
this should be regarded as a reference as the estimated
splice loss may not be correct in some cases, depending on
fiber properties. A power meter is recommended for correct
splice loss measurements.
AT2
(SM)(DS)(MM)
This mode allows the users to set a starting core offset value
and a finishing core offset value. Set [Start Offset] manually
and then splicing starts. Re-arcing is performed continuously /
automatically until the axial offset reaches [Stop Offset] value.
A splice loss estimate is not performed.
Editing Splice Mode
Splicing parameters in each splice mode can be modified. Arc power and Arc
time are considered the two most vital parameters.
To edit parameters follow the steps below:
1.
Select the icon in the [Splice Mode] screen, to show the splice mode.
2.
The category is displayed to the left. The parameters included in the
category are displayed on the right.
3.
Select and change the category icon and find the target parameter.
4.
Select the parameter displayed on the right side to show the parameter
edit screen.
5.