4. Adjustment
FinePix S602 ZOOM SERVICE MANUAL
48
4-3-6.Customizing of Adjustment Software
Customizing for the adjustment software is
explained below.
1.Compiles
Procedure <Fig.3-12>
1) Click on Mode Setting from the basic software
program’s menu bar. The “Customize” dialog box
will be displayed.
2) From the “Customize” dialog box, select “Compile.”
3) Click the Select User Program button, then select
the file ‘FxS602Z.ff’.
4) Click the Select Editor button, then select
‘Write.exe.’
2.EVR
Procedure <Fig.3-13>
1) Select “EVR” from the “Customize” dialog box.
2) Conditions
etc(-V2)
Check
LANC page check
Check
3.Hardware
Procedure <Fig.3-14>
1) Select “Hardware” from the “Customize” dialog box.
2) Conditions
Etc
7 Segment (-7)
Debug Mode
Ignore Focus I/O
3)
4)
<Fig.3-12> Compile
<Fig.3-13> EVR
<Fig.3-14> Hardware
2)
2)
c:\finepix_s602zoom\fxS602z.ff
FinePix_S602Zoom
FxS602Z.ff