5-14
F02
Operation Method
Selects a source issuing a run command--keypad or external control signal input.
- If F02 = 0, 2, or 3, the inverter can run the motor by the
and
keys on the
built-in keypad. The motor rotational direction can be specified in two ways, ei-
ther by control signal input (F02 = 0) or by use of prefixed forward or reverse
rotation (F02 = 2 or 3).
When F02 = 0, to specify the motor rotational direction by control signal input,
assign the commands
FWD
and
REV
to terminals [FWD] and [REV], respectively.
Turn on the
FWD
or
REV
for the forward or reverse direction, respectively, and
then press the
key to run the motor.
- If F02 = 1, the inverter can run the motor by control signal inputs. To specify the
motor rotational direction, assign the commands
FWD
and
REV
to terminals
[FWD] and [REV], respectively. Turn on the
FWD
or
REV
for the forward or re-
verse direction, respectively. If both of
FWD
and
REV
are turned on simultane-
ously, the inverter immediately decelerates to stop the motor.
The table below lists the operational relationship between function code F02
(Running/Stopping and Rotational Direction), the
and
key operation, and
control signal inputs to terminals [FWD] and [REV], which determines the rotational
direction.
Control signal inputs to
terminals [FWD] and [REV]
Function
code F02:
Key on the
keypad
Function code E98
FWD
command
Function code E99
REV
command
Motor
rotational
direction
OFF OFF
Stop
ON OFF
Forward
OFF ON
Reverse
key
ON ON
Stop
OFF OFF
ON OFF
OFF ON
0
key
ON ON
Stop
OFF OFF
Stop
ON OFF
Forward
OFF ON
Reverse
1 Ignored.
ON ON
Stop
key
Forward
2
(forward/
fixed)
key
Ignored.
Stop
key
Reverse
3
(reverse/
fixed)
key
Ignored.
Stop
Содержание Frenic Mini FRN001C1E-2U
Страница 60: ...3 15 Figure 3 5 shows the status transition for Menu 1 Data setting Figure 3 5 Data Setting Status Transition ...
Страница 85: ...5 4 ...
Страница 88: ...5 7 ...
Страница 89: ...5 8 C codes Control Functions of Frequency ...
Страница 92: ...5 11 J codes Application Functions y codes Link Functions ...
Страница 167: ...8 6 8 3 Common Specifications ...
Страница 168: ...8 7 ...
Страница 171: ...8 10 8 5 External Dimensions 8 5 1 Standard models ...
Страница 172: ...8 11 ...
Страница 173: ...8 12 8 5 2 Models available on order EMC filter built in type ...
Страница 174: ...8 13 ...
Страница 192: ...MEMO ...
Страница 193: ...MEMO ...
Страница 194: ...MEMO ...
Страница 196: ...Fuji Electric FA Components Systems Co Ltd Fuji Electric Corp of America 2007 06 F07 F07 00CM ...