8-1
Chapter 8 SPECIFICATIONS
8.1 Standard
Models
8.1.1 Three-phase
208V
001
002 003 005 007 010 015 020 025
030
040 050 060 075
100
125
1
2
3
5
7.5
10
15
20
25
30
40
50
60
75
100
125
1.6
2.7
3.8
6.0
9.0
11
16
21
27
31
41
51
60
76
98
123
4.6
7.5
10.6 16.7
25
31
47
60
75
88
114 143 169 211
273
343
3.1
5.8
8.7
14.5 20.6 27.5 41.3 55.1 68.8 82.6 109 134 160 199
270
333
5.1
9.1 12.9 21.5 30.8 40.8 59.4 76.6 94.0 110
144 179 215
-
-
-
1.2
2.2
3.2
5.3
7.5
10
15
20
25
30
40
49
58
72
98
120
7.1
(3.2)
7.3
(3.3)
7.3
(3.3)
7.5
(3.4)
13
(5.8)
13
(6.0)
15
(6.9)
21
(9.7)
21
(9.7)
25
(11.5)
51
(23)
73
(33)
75
(34)
90
(41)
90
(41)
265
(120)
*1 Standard 4-pole motor
*2 Rated capacity is calculated by assuming the output rated voltage as 208V for three-phase 208V.
*3 Output voltage cannot exceed the power supply voltage.
*4 An excessively low setting of the carrier frequency may result in the higher motor temperature or tripping of the inverter by its overcurrent
limiter setting. Lower the continuous load or maximum load instead. (When setting the carrier frequency (F26) to 1kHz, reduce the load to
80% of its rating.)
*5 Use [R1,T1] terminals for driving AC cooling fans of an inverter powered by the DC link bus, such as by a high power factor PWM
converter. (In ordinary operation, the terminals are not used.)
*6 Calculated under Fuji-specified conditions.
*7 Obtained when a DC reactor (DCR) is used.
*8 Average braking torque (Varies with the efficiency of the motor.)
Max. voltage(V) - Min. voltage(V)
Three-phase average voltage(V)
If this value is 2 to 3%, use an AC reactor (ACR).
UL508C, C22.2 No.14, EN50178-1997
Voltage unbalance(%)=
*9
Mass
〔
lbs(kg)
〕
IP00, UL open type
Fan cooling
IP20, UL open type
DC reactor (DCR)
Br
ak
in
g
Cooling method
Applicable safety standards
DC injection braking
Enclosure (IEC60529)
Standard
Option
Type (FRN _ _ _ F1S-2U)
Overload capability
Rated frequency
50, 60Hz
O
ut
put
r
at
ing
s
Nominal applied motor
〔
HP
〕
Rated capacity
〔
kVA
〕
Rated voltage
〔
V
〕
Rated current
〔
A
〕
Three-phase, 200 to 240V, 50/60Hz
Single-phase, 200 to 240V, 50/60Hz
Main power supply
Auxiliary control
power input
In
p
ut ra
tin
g
s
Rated current
〔
A
〕
Voltage/frequency variations
(with DCR)
(without DCR)
Auxiliary fan
power input
Phases,
voltage,
frequency
Single-phase, 200 to 230V, 50/60Hz
Torque
〔
%
〕
Required power supply capacity
〔
kVA
〕
10 to 15
20.0
None
Item
Specifications
×
67(IEC61800-3(5.2.3))
Starting frequency: 0.0 to 60.0Hz, Braking time:0.0 to 30.0s, Braking level: 0 to 60%
Voltage: +10 to -15% (Voltage unbalance 2% or less) *9, Frequency: +5% to -5%
120% of rated current for 1min.
Three-phase, 200V to 240V (With AVR function)
Three-phase, 200V to 230V (With AVR function)
Three-phase, 200 to 220V, 50Hz
Three-phase, 200 to 230V, 60Hz
Single-phase, 200 to 220V, 50Hz
Single-phase, 200 to 230V, 60Hz
*1
*2
*3
*4
*5
*7
*8
cooling
Natural
C22.2 No.14
UL508C
*6
Содержание FRENIC-ECO
Страница 111: ...5 3 F codes Fundamental Functions The shaded function codes are applicable to the quick setup...
Страница 114: ...5 6 F code continued...
Страница 115: ...5 7 E codes Extension Terminal Functions...
Страница 116: ...5 8 E code continued...
Страница 119: ...5 11 E code continued...
Страница 121: ...5 13 P codes Motor Parameters The shaded function codes are applicable to the quick setup...
Страница 122: ...5 14 H codes High Performance Functions...
Страница 123: ...5 15 H code continued...
Страница 126: ...5 18 J code continued...
Страница 127: ...5 19 J code continued...
Страница 128: ...5 20 y codes Link Functions...
Страница 129: ...5 21 y code continued...
Страница 141: ...5 33 Example of Operating Characteristics...
Страница 217: ...8 6 8 3 Common Specifications...
Страница 218: ...8 7...
Страница 223: ...8 12 8 5 External Dimensions 8 5 1 Standard models Unit inch mm 10 2 260...
Страница 227: ...8 16 8 5 3 Multi function Keypad Unit inch mm...
Страница 246: ...Fuji Electric FA Components Systems Co Ltd Fuji Electric Corp of America 2007 11 K07 K07 10CM...