Set reaction
Limit signal
(WORD 1 / Byte
2 / Bit 19)
Error number
(WORD 8 / Byte
16 - 17 / Bit 128
- 134)
Warning num-
ber (WORD 9 /
Byte 18 - 19 /
Bit 144 - 159)
Stop weld-
ing: yes /
no
Ignore
-
-
-
-
Warning
x
-
-
-
Error
x
x
-
Yes
Setting of the
reaction when
exceeding or fall-
ing below the lim-
its for the motor
force
General information
-
Motor force monitoring is not linked to a job and is therefore always available
-
In order to draw conclusions about the condition of the wire feed section (wear of the
inner liner, condition of the motor, etc.), the motor force can be monitored and a cor-
responding reaction can be set if the defined limits are exceeded or undershot
-
Motor force monitoring is available from version 2.3.1 of the power source onwards
-
The motor force of the main motor M1 is monitored
-
Motor force monitoring is also active during the threading process
The setting is used for:
-
Determination of how the power source reacts when the set limit for the motor force
is exceeded or undershot
The following reactions are possible:
-
Ignore
-
Warning
-
Errors
The following is a description of each reaction.
Reaction when limits are exceeded or undershot = ignore:
-
No reaction at the power source
-
No entry is made in the logbook
Reaction when limits are exceeded or undershot = Ignore
80
Содержание TPS/i
Страница 2: ......
Страница 73: ...Reaction when limits are exceeded or undershot Warning Overview of the entries in the logbook 73 EN US...
Страница 77: ...Reaction when limit exceeded limit undershot error Error message 77 EN US...