Wirefeeder monitoring
Adjustable parameters:
(1)
Wirefeeder set value:
0 to 100 m/min
(2)
Lower wirefeeder limit:
-10 to 0 m/min
(3)
Upper wirefeeder limit:
0 to 10 m/min
(4)
Time limit for the reaction of Limit Monitoring:
Off / 0 to 10 seconds
Explanation for setting from 0 to 10 seconds:
-
If, for example, 5 seconds are set, Limit Monitoring will only react after a limit
has been exceeded or undershot continuously for 5 seconds
Explanation for "Off" setting:
-
Limit Monitoring is disabled for this welding parameter
-
There is no display of limit overruns
Possible error messages during wirefeeder monitoring:
23 |
Lower wirefeeder limit undershot
24 |
Upper wirefeeder limit exceeded
Welding time
monitoring
Serves to:
-
Set the welding time set value and the desired limits
-
Monitor the welding time per weld seam / job
If a weld seam consists of 2 or more jobs, the welding time of the previously welded job
must be added for the jobs following in the welding sequence.
69