WireSense start -
Single Bit
WARNING!
Danger from electrical current. When the WireSense start signal is active, a
voltage of approx. 50 V (up to 1 A) is applied to the wire electrode/contact tip.
This may result in serious injuries or death.
▶
Do not touch the wire electrode and contact tip when the WireSense start signal is
active.
▶
Do not touch any electrically conductive parts that are touched by the wire electrode
or the contact tip when the WireSense start signal is active.
This signal starts one of the following two functions:
1.
WireSense - Sensing Mode: used to scan the component surface / component geo-
metry (contour detection)
-
This function is active when the Signal WireSense start is activated and a height
value less than 0.5 mm (0.019 inches) is specified for the WireSense edge
detection signal
-
Edge detection is not active with this function
-
The Touch signal is not output for this function
2.
WireSense - Edge Detection Mode: used to detect a single edge
-
This function is active when the Signal WireSense start is activated and a height
value greater than / equal to 0.5 mm (0.019 inches) is specified for the Wire-
Sense edge detection signal
-
For more information, see
WireSense edge detection - Group Input / Analog
Other effects of the WireSense start signal:
-
As soon as the signal is active, the forward and backward movement of the wire
electrode begins
-
After the wire electrode has touched the workpiece for the first time, the point of the
first contact is used as a zero position (reference point) for the WireSense height
measurement
Safety functions with WireSense:
-
If WireSense is already active (WireSense process already running), the wire elec-
trode can be conveyed a maximum of 25 mm (0.98 inches). If there is no workpiece
contact within the 25 mm (0.98 inches), wirefeeding is stopped.
-
If WireSense is started for the first time (without previous workpiece contact), the
wire electrode can be conveyed a maximum of 450 mm (17.72 inches). If there is no
workpiece contact within 450 mm (17.72 inches), wirefeeding is stopped.
For more information on WireSense, see section
page
18