Fronius Data Channel
Fronius Data
Channel
A variety of signals and data can be written and exchanged between the power source
and a control unit (robot controller, etc.) via the Ethernet connection on the rear of the
power source (service port).
In order to be able to use the Fronius Data Channel, OPT/i Documentation must be
enabled for the power source.
On TWIN systems, the Ethernet connection socket on the power source of process line 1
must be used.
Available signals and data:
Number
Designation
Description
Type of signal
1
Process active
1/0
Output
2
Current flow
1/0
Output
3
Article number
String
Input
4
Serial number
String
Input
5
Seam number
Integer
Input
Windows example (PuTTY)
A TCP socket connection must be estab-
lished for data transfer.
1
For this purpose, enter the IP address
of the power source service port and
the port number 4714.