Value range
Designation
Min./max. possible value
0 V
Welding current
0 A (set value/actual value/Hold value)
10 V
Welding current
1000 A (set value/actual value/Hold value)
Additional information for TWIN systems:
The analog actual value is not output on TWIN systems.
Wire feed speed
(Wire speed) -
Group Output /
Analog Output
As described below, the current wire speed actual value can be output on a Digital Inter-
face or an Analog Interface.
Digital Interface:
-
During the welding process, the current wire speed actual value will be output as
a value between -32,768 and +32,767 (SINT 16) .
-
The wire speed set value is output when idling.
-
The Hold- value is output immediately after welding.
Value range
Designation
Min./max. possible value
-32,768
Wire speed
-327.68 m/min (set value/actual value/Hold
value)
+32,767
Wire speed
+327.67 m/min (set value/actual value/Hold
value)
Additional information for TWIN systems:
The digital actual value is output separately for both power sources.
Analog Interface:
-
During the welding process, the current wire speed actual value will be output
using an analog method as a value between 0 - 10 V.
-
The wire speed set value is output when idling.
-
The Hold- value is output immediately after welding.
Value range
Designation
Min./max. possible value
0 V
Wire speed
0 m/min (set value/actual value/Hold value)
10 V
Wire speed
depending on the wirefeeder used
Additional information for TWIN systems:
The analog actual value is not output on TWIN systems.
Actual real value
for seam tracking
(Current actual
value for seam
tracking) - Group
Output / Analog
Output
As described below, the current actual value for seam tracking can be output on a Digital
Interface or an Analog Interface.
This signal is output as standard when using MIG/MAG LSC and MIG/MAG PMC char-
acteristics. The signal is available upon request for MIG/MAG pulse synergic and
MIG/MAG standard synergic characteristics.
Digital Interface:
-
During the welding process, the current actual value for seam tracking will be
output as a value between 0 and 65,535 (UINT 16).
-
The Hold- value is output at the end of welding.
Value range
Designation
Min./max. possible value
38