The following signals can be set on the power source itself if the Parameter selection
internally High signal is active:
-
Welding process (MIG/MAG pulse synergic, MIG/MAG standard synergic, etc.)
-
Operating mode (2-step mode, etc.)
-
Characteristic/job number (depending on the welding process)
-
Wire speed
-
Arc length correction
-
Pulse/dynamic correction
-
Wire retraction
-
Process-dependent correction
-
SynchroPulse on/off
Additional information for TWIN systems:
The signal is set to High as soon as parameter selection is set to "internal" on one of the
two process lines.
Limitsignal (Limit
signal) - Single
Bit
This signal indicates that the set limits for voltage, current, wirefeeder, welding time, and
energy input have been exceeded or not reached.
This signal is only available in Job Mode.
Requirements
-
In the menu on the power source "Process parameters/Job/Optimize Job/Limit mon-
itoring/Limit reaction", the reaction is set to "Warning" or "Error"
-
OPT/i Limit Monitoring approved for the power source
Additional information for TWIN systems:
The signal is output separately for both process lines.
For more information on Limit Monitoring see section:
-
Limit Monitoring - functions and activation
-
Limit Monitoring - details on the individual welding parameters
Main supply
status (Mains
voltage status) -
Single Bit
This signal indicates whether a phase error has occurred on the power source (incorrect
power supply to the power source).
If this error has occurred, the error numbers 6451 or 6515 will be shown on the display of
the power source or transmitted to the robot via the interface as an Error number signal
Additional information for TWIN systems:
The signal is set to High as soon as a phase error occurs on one of the two power
sources.
Safety status -
Single Bit
This signal indicates the status of the OPT/i Safety Stop PL d and OPT/i TPS External
Stop options.
Bit 1
Bit 0
Description
0
0
Reserve
0
1
Hold
1
0
Stop
1
1
Not installed/active