![Fronius TPS/i Скачать руководство пользователя страница 49](http://html1.mh-extra.com/html/fronius/tps-i/tps-i_user-information_2339420049.webp)
Signal sequence when selected using "Job Mode"
operating mode
Robot ready
Power source ready
Error number
Working mode
(Job mode)
(1)
Job number
Welding start
Process active
Arc stable
Robot motion release
Main current signal
(3)
(2)
(6)
(4)
(5)
(7)
(1)
Wait time of at least 0.1 seconds
(2)
Wait time of at least 0.1 seconds
(3)
Gas pre-flow time
(4)
Starting current time
(5)
Slope 1
(6)
Gas post-flow time
(7)
Slope 2 + final current time