Description of special 2-step mode characteristics:
-
To select welding parameters using the analog set values and the characteristic
number (characteristic ID), the correct characteristic number must be used. The
characteristic numbers can be found on the website of the power source, in the
characteristics overview.
-
The welding process is also defined using the characteristic number (MIG/MAG
standard synergic, MIG/MAG pulse synergic, MIG/MAG LSC, MIG/MAG PMC,
MIG/MAG CMT, etc.).
-
Only characteristics that have previously been approved for the power source can
be selected.
-
The parameters from the start of welding/end of welding are used in the special 2-
step mode characteristics.
I
I-S
I-E
I
S
E
GPr
GPo
SL1
Main current
SL2
t
t-S
Welding start
t-E
HIGH
LOW
Special 2-step mode signal sequence
Description of Job Mode:
-
The welding parameters are selected using the data saved in the jobs.
-
The EasyJob function is deactivated as soon as a CC module (an RI IO/i or a RI IO
PRO/i) is connected.
-
There is no job with the number 0. Job number 0 can be used to select the job on
the control panel of the power source.
Description of 2-step mode characteristics:
-
To select the welding parameters via the analog set values and the characteristic
number (characteristic ID), the correct characteristic number must be used. The
characteristic numbers can be found on the website for the power source, in the
characteristics overview.
-
The welding process is also defined using the characteristic ID (MIG/MAG standard
synergic, MIG/MAG pulse synergic, MIG/MAG LSC, MIG/MAG PMC, MIG/MAG
CMT, etc.).
-
Only characteristics that have previously been approved for the power source can
be selected.