Detailed descrip-
tion of Limit Mon-
itoring
-
Limit Monitoring is only active in the main current phase
-
The data is recorded / checked every 50 ms during Limit Monitoring
-
At point A, the upper voltage limit is exceeded; the time until the reaction of Limit
Monitoring begins to count constantly upwards
-
At point B, the voltage falls below the upper limit again; the time until the reaction of
Limit Monitoring counts down to 0
-
At point C, the upper voltage limit is exceeded again; the time until the reaction of
Limit Monitoring starts to count upwards constantly again
-
At point D, the set time limit for the reaction of limit monitoring is reached
-
The hysteresis time starts to run
-
Point E shows the hysteresis of +20% to the set time value (time until reaction
from Limit Monitoring)
-
A warning or an error is issued depending on the setting
-
The Limitsignal (Word 1 / Byte 2 / Bit 19) changes to High
-
At point F, the Limitsignal (Word 1 / Byte 2 / Bit 19) changes to Low
Functionality of Limit Monitoring for energy and welding duration:
-
With energy monitoring, Limit Monitoring does not monitor each job individually, but
the entire weld seam - for more information see
-
With welding time monitoring, Limit Monitoring does not monitor each job individu-
ally, but the entire weld seam - for more information, see
from page
66