Fitting the nozzle:
IMPORTANT!
When fitting the nozzle, ensure that:
-
The O-ring on the nozzle is present and OK
-
The O-ring is greased
CAUTION!
Danger from nozzle being thrown out of the device.
An incorrectly secured nozzle can be thrown out of the device when compressed air is
supplied and cause a variety of injuries.
▶
The sequence of the following steps must be observed.
▶
Always insert the nozzle as far as it will go.
▶
Check that the nozzle is correctly secured.
1
Pull out and hold the spring bolt
2
Insert the nozzle as far as it will go
3
Release the spring bolt and make sure it engages
4
Fit cover