35
1. Set the "Start LEFT / STOP / Start RIGHT" toggle switch to the "STOP" (0) position.
Interval
welding
2. Press the "SELECT / ENTER" button for 3 seconds to enable parameter entry. Every
time you access the set-up menu, the "welding segment" parameter is automatically
displayed.
3. Press the "+ / -" buttons and set the desired welding segment (e.g. "10.0 cm"). Press
the "SELECT / ENTER" button to accept the value. The next parameter is selected.
4. Press the "+ / -" buttons and set the desired pause segment (e.g. "5.0 cm"). Press
the "SELECT / ENTER" button to accept the value. The next parameter is selected.
3 sec.
For interval welding, the welding segment and pause segment distances can be set sep
-
arately. Welding stops after the total path has been travelled. If no total path is defined,
the driving vehicle stops through actuation of the front or rear limit switch. The following
parameters must be set for interval welding:
- Welding segment [cm]
- Pause segment [cm]
- Duration of crater filling [s]
- Duration of back-filling [s]
- Total path [cm] (if desired)
Proceed as follows: