31
Start-up
WARNING!
Operating the equipment incorrectly can cause serious injury and
damage. Do not use the functions described until you have thoroughly read
and understood the following documents:
- these operating instructions
- all the operating instructions for the system components, especially the
safety rules
The following activities and work steps apply to the installed system. All connections
must be established. Before start-up, check the connections of the following system com
-
ponents:
- Power source
- Cooling circuit
- Gas cylinder
- Wire-feed unit
- Welding torch with hosepack
Precise information on the assembly and connection of the system components can be
found in the relevant system component operating instructions.
Check the con-
nections
IMPORTANT!
There are no fixed rules for the sequence in which the system compo
-
nents are switched on. They can be switched on in any order.
On the following system components turn the main switch to the "ON - 1" position:
- Driving vehicle control unit
- Power source
- Wire-feed unit (if power is not supplied from the power source)
Switch on
system compo-
nents
WARNING!
Danger of injury from premature arc ignition
The arc may be ignited accidentally. This can lead to serious eye injury.
Before switching on the system components, make sure that the "Start LEFT
/ STOP / Start RIGHT" toggle switch on the driving vehicle control panel is set
to the "STOP" position.
Set the following welding process parameters on the driving vehicle:
- Traversing speed
- Welding segment
- Pause segment
- Crater-filling
- Back-filling
- Total path
- Oscillation parameters (mode, dwell times, oscillation speed, oscillation path)
- Position the contact cam (with continuous welding)
For detailed information about entering the driving vehicle parameters, see the section
"Setting the driving vehicle parameters".
Define driving
vehicle param-
eters
Содержание 8,045,368
Страница 2: ......
Страница 52: ...50...
Страница 53: ...1 Spare parts...
Страница 54: ...2...
Страница 55: ...3 Carriage FDV 22 MF Art Nr 8 045 368 incl 48 0005 1217 nur Stecker plug only 48 0005 1182...
Страница 56: ...4 Torch holder for second torch Additional torch holder Art Nr 48 0005 1893 Carriage FDV 22 MF Art Nr 8 045 368...
Страница 58: ...6 Circuit diagram...
Страница 59: ...7 EU Declaration of conformity...
Страница 60: ...FRONIUS INTERNATIONAL GMBH TechSupport Automation www fronius com addresses www fronius com...