Torch body coupling does not open
Cause:
Compressed air supply of torch body changeover station too low
Remedy:
Ensure compressed air supply is as per the specifications in the operating in-
structions
Torch body coupling does not open
Cause:
Incorrect output pressure set on the compressed air amplifier
Remedy:
Adjust compressed air amplifier as per the specifications in the operating in-
structions
Torch body coupling does not open
Cause:
Torch body coupling is faulty
Remedy:
Press the emergency release button and service the centre bolt as per the op-
erating instructions. If this does not remedy the problem, send the torch body
coupling to the manufacturer's service department.