51
EN
Setting the wire
sensor
Rotate the wire electrode in the
opening (2) of the wire sensor (1) du-
ring the entire setting process
-
LED (4) comes on if the wire sen-
sor (1) detects the wire electrode
Turn the adjusting screw (3) in the re-
verse direction until the LED (4) goes
off
-
Wire sensor is deactivated
Only turn the adjusting screw (3) until
the LED (4) comes on again
-
Wire sensor (1) is now set at the
lowest sensitivity level
-
This prevents the wire sensor from
being triggered accidentally
(4)
(3)
(2)
(1)
1
2
3
Содержание 4,044,008