REMOVAL AND REPLACEMENT OF PARTS
Page 47
Service Manual Deli Multisserie form 9123667 rev. 20220317
10
10
11
11
14
14
4x
12
12
13
13
18
18
17
17
15
15
6,3
2,8
6,3
Core probe
Upper sensor
Lower sensor
117
118
10. Tie the wires together.
11. Pull the wire up through the side post .
12. Twist the new sensor ±4 turns ccw. (after
mounting, the wire will have no stress)
13. Mount the sensor with the sensor protec-
tion. Use some thread sealant.
14. The wires can be connected with help
of splices. Twist and fold the wire for the
best contact. See below for official con-
nections.
Note that bad contacts will result in bad
temperature reading, causing bad cooking
results!!!!
Each contact is a potential risk. Therefore,
the best way is to lead the wires from the
top and bottom sensor, all the way to the
I/O board.
15. Open the service doors at the back. [551]
[4 screws].
16. Disconnect the 2 capacitors [51] from the
ventilator motors.
17. Take the hose with the grommet out of
the transit hole.
18. Remove the vertical air suction channel.
[268] (2 nuts M6 en 2x nut/bolt M5)
19. Cut the old wires loose from the wiring
loom and take them out.
20. Lead the new sensor wires to the board.
20. Clamp female receptacles to the wires.
(The “normal” red receptacles 6,3 and 2,8
are also possible.
Default
Slot down!
Содержание Deli Multisserie
Страница 2: ...TABLE OF CONTENTS Page 2 Service Manual Deli Multisserie form 9123667 rev 20220317 EMPTY PAGE...
Страница 69: ...ELECTRICAL TESTS Page 69 Service Manual Deli Multisserie form 9123667 rev 20220317...
Страница 85: ...TROUBLE SHOOTING Page 85 Service Manual Deli Multisserie form 9123667 rev 20220317 EMPTY PAGE...
Страница 127: ...Page 127 ELECTRICAL DIAGRAMS Service Manual Deli Multisserie form 9123667 rev 20220317 EMPTY PAGE...