![Freescale Semiconductor QE128 Скачать руководство пользователя страница 71](http://html1.mh-extra.com/html/freescale-semiconductor/qe128/qe128_quick-reference-user-manual_2330661071.webp)
Using the Analog Comparator (ACMP) for the QE Microcontrollers
QE128 Quick Reference User Guide, Rev. 1.0
Freescale Semiconductor
7-7
ACMP module can operate with two external inputs. This example code is
expressly made to configure the ACMP module to work using the internal
reference voltage.
The analog comparator circuit is designed to operate across a full range of
supply voltage. Please refer to the data sheet of the device. You can also find
it at www.freescale.com.
Figure 7-3
, shows the hardware connections used for the ACMP project, for
detailed information about the MCU supply voltages needed, please refer to
the Pins and Connections chapter the Reference Manual (MC9S08QE128 or
MCF51QE128). It can also be found at www.freescale.com.