background image

 

 

8

 

A.

 

Ensure the wires are seated in the connector securely.

 

B.

 

Check the wiring harness for damage or breaks in the wiring insulation. 

 

C.

 

Check the wiring on the LVCB.  The connection point on the LVCB is in the upper left corner and labeled as TB18.   
Ensure the wires are securely in place in the connector and the board. 

 

3.

 

Measure the resistance of the thermistor at the control board.  Disconnect the TB18 connector and measure the            
resistance through the purple wires.  It should measure 3K

-

10K ohms.  If out of range, replace 

BF Steamer Heater

 (Parts 

Manual: Heaters & Position Motor).

 

 

Error 70: 

Chamber Thermistor Shorted or Open

 

TRIGGER: A short or open of the chamber thermistor is detected by the LVCB

 

1.

 

Reset the blender by pressing “Regular” & “More Thick” buttons together for 7 seconds 

to soft

-

reset the blender

.

 

2.

 

Check the Chamber Thermistor wires and connector.  The thermistor is located by removing the left side panel.  The   
thermistor is located at the lower left corner of the chamber.  The wires are black and attached to the blending chamber 
behind a small metal shield and a foam piece. 

 

A.

 

Ensure the wires are seated in the connector securely.

 

B.

 

Check the wiring harness for water damage or breaks in the wiring insulation. 

 

C.

 

Check the wiring on the Low Voltage Control Board (LVCB). The connection point on the LVCB is in the upper left  
corner and labeled as TB18.  Ensure the wires are securely in place in the connector and the board. 

 

3.

 

Measure the resistance of the thermistor on the LVCB. Disconnect the TB18 connector and measure the resistance 
through the blue wires.  It should measure 3k

-

10K ohms.  If out of range, replac

Chamber Thermistor

 (Parts Manual:    

Glossary).

 

 

Error 71: 

Scour Thermistor Shorted or Open

 

TRIGGER: A short or open of the scour is detected by the LVCB

 

1.

 

Reset the blender by pressing “Regular” & “More Thick” buttons together for 7 seconds 

to soft

-

reset the blender

.

 

2.

 

Check the Scour Thermistor wires and connector.  The thermistor is located by removing the left, right and rear panels.  
The thermistor is located at bottom of the smaller heater.  The wires are red.  

 

A.

 

Ensure the wires are seated in the connector securely.

 

B.

 

Check the wiring harness for damage or breaks in the wiring insulation. 

 

C.

 

Check the wiring on the Low Voltage Control Board (LVCB). The connection point on the LVCB is in the upper left  
corner and labeled as TB18.  Ensure the wires are securely in place in the connector and the board. 

 

3.

 

Measure the resistance of the thermistor at the control board.  Disconnect the TB18 connector and measure the            
resistance through the red wires. It should measure 3

-

10K ohms.  If out of range, replace 

Scour Heater

 (Parts Manual: 

Heaters & Position Motor).

 

 

Error 74: 

Time

-

Out Occurred During Homing

 

TRIGGER: Any homing time

-

out parameter exceeded

 

1.

 

Reset the blender by pressing “Regular” & “More Thick” buttons together for 7 seconds 

to soft

-

reset the blender

.

 

2.

 

Verify that the travel path of the Cup Holder is clear. 

 

Remove any obstacles.

 

3.

 

Bring up the LVCBS Status Screen (Press the “Left Arrow” & “OK” buttons for 7 seconds until the Status Screen appears on 
the screen) and locate Line Q: “HomeSn: 1/0” 

 

A.

 

If the Cup Holder is in its home position and “HomeSn: 1”, proceed to Step 4.

 

B.

 

If the Cup Holder is in its home position and “HomeSn: 0”, replace 

Through

-

Beam Sensor

 (Parts  Manual: Switches, 

Sensor & Solenoid Lock) and proceed to Step 4.

 

4.

 

Inspect the back of the Accumulator Tank to verify there is no leak coming out of the metal fitting that could short out the 
sensor.

 

 If there is a leak, replace 

Accumulator Tank

 (Parts Manual: Water System).

 

5.

 

Check to see if the Cup Holder will re

-

home: 

 

A.

 

Turn the blender off, manually pull up on the Cup Holder 3

-

4 inches.

 

 Turn the blender back on.

 

 The Cup Holder 

should re

-

home, or lower back down, after the boot up process.

 

 If the Cup Holder doesn't return to the home     

position, replace 

Position Motor 

(Heaters & Position Motor).

 

Содержание FRLB4

Страница 1: ...1 Rev J Model FRLB4 Service Manual...

Страница 2: ...2...

Страница 3: ...completely HEY Please close the front door OOPS Something s in the way of the cup holder OOPS Wrong cup size HEY The product is not cold enough to be blended WE RE SO SORRY The blender needs to take a...

Страница 4: ...p Door to clean off any product build up around the blending chamber rim and gasket Be careful not to damage the gasket Panels Screens 4 2 Daily Blender Maintenance 1 2 Weekly Blender Maintenance Loca...

Страница 5: ...ht Arrow OK Recover Catastrophic Error Regular More Thick Initiate Manual Water Shot Rinse Less Thick Initiate Manual Scour Rinse Regular Initiate Manual Rotary Rinse More Thick Initiate Steam Cycle L...

Страница 6: ...ting up on the bottom of the Cup Holder If you are unable to raise the Cup Holder replace Position Motor Parts Manual Heaters Position Motor Error 66 Pump Motor Peak Current Limit Exceeded TRIGGER Pum...

Страница 7: ...ace Flip Up Door Shoe Parts Manual Switches Sensor Solenoid Lock Error 6B Home Sensor Malfunction During Blend TRIGGER Home sensor blocked or unblocked at the wrong carriage location 1 Reset the blend...

Страница 8: ...ns together for 7 seconds to soft reset the blender 2 Check the Scour Thermistor wires and connector The thermistor is located by removing the left right and rear panels The thermistor is located at b...

Страница 9: ...ly proceed to Step 10 7 Verify the BF Steamer Heater is heating properly A Verify wiring at the steamer tank is intact and correct B Check for continuity through steamer elements with a Multi Meter a...

Страница 10: ...wer c If water is not continuously spraying proceed to Step 6 6 Check that the amount of water dispensed is being accurately registered by the Flow Meter A Remove the Water Shot Hose from the blending...

Страница 11: ...tch the Count on Line J of the Status Screen If not replace Flow Meter Parts Manual Water System E If the amount of water in the cup matches the Count on Line J and is still 65mL and error returns ens...

Страница 12: ...buttons for 7 seconds until the Status Screen appears on the screen and locate Line E ScrTemp XXX A If the ScrTemp does not reach the Trigger temperatures above or by passes it for more than 1 minute...

Страница 13: ...The fuse is located on the LVCB at F1 If the fuse is blown replace LVCB Parts Manual Control Boards Lower 5 Measure DC voltages for the Position Motor on the LVCB at TB5 A At rest Red wire pin to grou...

Страница 14: ...re inside the chamber matches the ChmTemp a If the temperatures are the same ensure blender has the latest Firmware Version Press the Left Arrow OK buttons for 7 seconds until the Status Screen appear...

Страница 15: ...e Left Arrow OK buttons for 7 seconds until the Status Screen appears on the screen and locate Line J Count XXXX mL a If the amount in the cup is either less or more than what is on the Count XXXX mL...

Страница 16: ...the chamber Next remove the right side panel and locate the switch behind the metal tab on the front of the blender 4 Bring up the LVCBS Status Screen Press the Left Arrow OK buttons for 7 seconds un...

Страница 17: ...s between 0 6 F A Perform the Squeeze Test Using a chocolate milkshake squeeze the middle of the cup You should be able to squeeze a dime size dent in the milkshake B Ensure the product is tempered se...

Страница 18: ...he SBC is a Zotac ensure the USB connections are secure if they are and the issue remains replace with a V1 Single Board Computer Parts Manual Control Boards Lower B If the SBC is a Jetway NC98 2 fans...

Страница 19: ...e blender back on at the same time i If the fans start up and the blender boots up in a normal process remove the screwdriver re connect the SBC Reset connection and return the panels ii If the fans s...

Страница 20: ...ion Do not slam the door Slamming the door will damage the LCD touchscreen 2 If the door still won t close slowly close the front door and watch where the front door latch meets the blender frame If t...

Страница 21: ...shim the wedge out a Add another washer between the back of the LCD screen and Front Door Wedge on the bottom 2 corners This will add more pressure on the bottom of the Front Door Wedge and chamber op...

Страница 22: ...hould be able to squeeze a dime size dent in the milkshake ii If you can put a dent in the side of the shake during the squeeze test the product is ready to move into the front display freezer Blender...

Отзывы: