Error 93: 

Scour Tank Recharge Timeout

 

TRIGGER: Scour Heater minimum recharge flow of 15mL was not reached within 8 seconds

 

1.

 

Reset the blender by pressing “Regular” & “More Thick” buttons together for 7 seconds to soft

-

reset the blender.

 

2.

 

Ensure blender

 

has the latest Firmware Version.

 

A.

 

Press the “Left Arrow” & “OK” buttons for 7 seconds until the Status Screen appears on the screen.  Locate “FWXXXX” in 
the top right corner.  FW Version should be FW0330.

 

3.

 

Ensure water supply is on and regulated to 25 

-

 65 PSI.

 

4.

 

Verify Water Pressure Regulator

 

is installed correctly with an arrow pointing in the direction of the water flow.  If damaged,  

replace 

Water Pressure Regulator 

(Parts Manual: Glossary).

 

A.

 

SN 19783D and later will have an Internal Water Pressure Regulator.

  

5.

 

Remove the Lower Scour Nozzle and clean as necessary.

 

 When cleaning, be sure not to enlarge the opening of the nozzle.    

Enlarging the nozzle will result in a different spray pattern, compromising the blender’s ability to clean itself.  When the nozzle is 
removed, close the front door and soft

-

reset to flush any debris from the line.  Replace nozzle and soft

-

reset again.

 

6.

 

If errors persist, replace the 

Manifold

 (Parts Manual: Water System).

 

 

Error 94: 

Steamer Thermal Shock Timeout

 

TRIGGER: Steamer thermal shock water event exceeded 30 seconds for 55mL of water

 

1.

 

Reset the blender by pressing “Regular” & “More Thick” buttons together for 7 seconds to soft

-

reset the blender.

 

2.

 

Ensure water supply is on and regulated to 25 

-

 65 PSI.

 

3.

 

Inspect Water Shot Orifice (WSO) for scale buildup.  Use a paperclip or similar item to clean the WSO.  In some cases, removing 
the Water Shot Hose connection at the top of the blending chamber is necessary to completely clean the WSO.

 

4.

 

If there are no signs of scale buildup and the blender has been subjected to water pressure greater than 65 PSI, replace        

Manifold

 (Parts Manual: Water System). 

 

5.

 

Check the amount of water flow coming from the water shot hose. 

 

A.

 

Remove the water shot hose from the back of the blending chamber. 

 

B.

 

Bring up the LVCBS Status Screen (Press the “Left Arrow” & “OK” buttons for 7 seconds until the Status Screen appears on 
the screen) and locate Line J: “Count XXXX mL”

 

a.

 

If the amount in the cup is either less or more than what is on the “Count XXXX mL”, replace 

Flow Meter

 (Parts   

Manual: Water System).

 

 

Error 95: 

Parameter Chucksum after Reading EEPROM

 

TRIGGER: At start

-

up, if parameter check fails

 

1.

 

Reset EEPROM. 

 

A.

 

To reset EEPROM, turn the blender off using the power switch and ensure there is no cup in the Cup Holder. 

 

B.

 

Press and hold the ‘left’ and ‘right’ arrow keys together and turn the blender on.

 

C.

 

Continue to hold the arrow keys down until the video/animation starts to play. 

 

D.

 

Try another blend cycle.  If error persists, replace the 

Low Voltage Control Board 

(Parts Manual: Control Boards, Lower).

 

 

Error 96: 

Extended Water Shot too Short in Duration

 

TRIGGER: The target volume of 5,000mL was reached faster than 10 seconds

 

1.

 

Reset the blender by pressing “Regular” & “More Thick” buttons together for 7 seconds to soft

-

reset the blender.

 

2.

 

Check for any continuous leaks inside the blender.  If any nozzles or orifices are running with the door open, replace 

Manifold

 

(Parts Manual: Water System). 

 

3.

 

Inspect the Water Shot Orifice inside the chamber.  Ensure this is not damaged in any way.  If it is, replace 

Chamber Assembly 

(Parts Manual: Inside the Chamber).

 

 

Error 97: 

Extended Water Shot too Long in Duration

 

TRIGGER: The target volume of 5,000mL was not reached in 900 seconds during water system purge

 

1.

 

Reset the blender by pressing “Regular” & “More Thick” buttons together for 7 seconds to soft

-

reset the blender.

 

2.

 

Ensure water supply is on and regulated to 25 

-

 65 PSI.

 

3.

 

Verify Water Pressure Regulator

 

is installed correctly with an arrow pointing in the direction of the water flow.  If damaged,  

replace 

Water Pressure Regulator 

(Parts Manual: Glossary).

 

A.

 

SN 19783D and later will have an Internal Water Pressure Regulator.

  

4.

 

Inspect Water Shot Orifice (WSO) for scale buildup.  Use a paperclip or similar item to clean the WSO.  In some cases, removing 
the Water Shot Hose connection at the top of the blending chamber is necessary to completely clean the WSO.

 

5.

 

If there are no signs of scale buildup and the blender has been subjected to water pressure greater than 65 PSI, replace        

Manifold

 (Parts Manual: Water System). 

 

 

Содержание FRLB4

Страница 1: ...1 Rev J Model FRLB4 Service Manual...

Страница 2: ...2...

Страница 3: ...completely HEY Please close the front door OOPS Something s in the way of the cup holder OOPS Wrong cup size HEY The product is not cold enough to be blended WE RE SO SORRY The blender needs to take a...

Страница 4: ...p Door to clean off any product build up around the blending chamber rim and gasket Be careful not to damage the gasket Panels Screens 4 2 Daily Blender Maintenance 1 2 Weekly Blender Maintenance Loca...

Страница 5: ...ht Arrow OK Recover Catastrophic Error Regular More Thick Initiate Manual Water Shot Rinse Less Thick Initiate Manual Scour Rinse Regular Initiate Manual Rotary Rinse More Thick Initiate Steam Cycle L...

Страница 6: ...ting up on the bottom of the Cup Holder If you are unable to raise the Cup Holder replace Position Motor Parts Manual Heaters Position Motor Error 66 Pump Motor Peak Current Limit Exceeded TRIGGER Pum...

Страница 7: ...ace Flip Up Door Shoe Parts Manual Switches Sensor Solenoid Lock Error 6B Home Sensor Malfunction During Blend TRIGGER Home sensor blocked or unblocked at the wrong carriage location 1 Reset the blend...

Страница 8: ...ns together for 7 seconds to soft reset the blender 2 Check the Scour Thermistor wires and connector The thermistor is located by removing the left right and rear panels The thermistor is located at b...

Страница 9: ...ly proceed to Step 10 7 Verify the BF Steamer Heater is heating properly A Verify wiring at the steamer tank is intact and correct B Check for continuity through steamer elements with a Multi Meter a...

Страница 10: ...wer c If water is not continuously spraying proceed to Step 6 6 Check that the amount of water dispensed is being accurately registered by the Flow Meter A Remove the Water Shot Hose from the blending...

Страница 11: ...tch the Count on Line J of the Status Screen If not replace Flow Meter Parts Manual Water System E If the amount of water in the cup matches the Count on Line J and is still 65mL and error returns ens...

Страница 12: ...buttons for 7 seconds until the Status Screen appears on the screen and locate Line E ScrTemp XXX A If the ScrTemp does not reach the Trigger temperatures above or by passes it for more than 1 minute...

Страница 13: ...The fuse is located on the LVCB at F1 If the fuse is blown replace LVCB Parts Manual Control Boards Lower 5 Measure DC voltages for the Position Motor on the LVCB at TB5 A At rest Red wire pin to grou...

Страница 14: ...re inside the chamber matches the ChmTemp a If the temperatures are the same ensure blender has the latest Firmware Version Press the Left Arrow OK buttons for 7 seconds until the Status Screen appear...

Страница 15: ...e Left Arrow OK buttons for 7 seconds until the Status Screen appears on the screen and locate Line J Count XXXX mL a If the amount in the cup is either less or more than what is on the Count XXXX mL...

Страница 16: ...the chamber Next remove the right side panel and locate the switch behind the metal tab on the front of the blender 4 Bring up the LVCBS Status Screen Press the Left Arrow OK buttons for 7 seconds un...

Страница 17: ...s between 0 6 F A Perform the Squeeze Test Using a chocolate milkshake squeeze the middle of the cup You should be able to squeeze a dime size dent in the milkshake B Ensure the product is tempered se...

Страница 18: ...he SBC is a Zotac ensure the USB connections are secure if they are and the issue remains replace with a V1 Single Board Computer Parts Manual Control Boards Lower B If the SBC is a Jetway NC98 2 fans...

Страница 19: ...e blender back on at the same time i If the fans start up and the blender boots up in a normal process remove the screwdriver re connect the SBC Reset connection and return the panels ii If the fans s...

Страница 20: ...ion Do not slam the door Slamming the door will damage the LCD touchscreen 2 If the door still won t close slowly close the front door and watch where the front door latch meets the blender frame If t...

Страница 21: ...shim the wedge out a Add another washer between the back of the LCD screen and Front Door Wedge on the bottom 2 corners This will add more pressure on the bottom of the Front Door Wedge and chamber op...

Страница 22: ...hould be able to squeeze a dime size dent in the milkshake ii If you can put a dent in the side of the shake during the squeeze test the product is ready to move into the front display freezer Blender...

Отзывы: